Evidence map›Paper›PMID 34724520›Full record

ArticleThe Analyst2021

Evaluation of table-top lasers for routine infrared ion spectroscopy in the analytical laboratory.

Rianne E van Outersterp, Jonathan Martens, André Peremans, Laurent Lamard, Filip Cuyckens, Jos Oomens, Giel Berden

Open access · hybridAbstract read
In one paragraph

Article in The Analyst, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 18 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. A Dynamic Proton Bond: MHThe journal of physical chemistry letters · 2023
    Article
  6. Article
  7. Laboratory IR Spectra of the Ionic Oxidized Fullerenes CThe journal of physical chemistry. A · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Rianne E van OutersterpRadboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands. g.berden@science.ru.nl.ORCID http://orcid.org/0000-0001-7493-2765
Jonathan MartensRadboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands. g.berden@science.ru.nl.ORCID http://orcid.org/0000-0001-9537-4117
André PeremansLaboratoire Physique de la Matière et du Rayonnement (P.M.R), Université de Namur, 5000 Namur, Belgium.
Laurent LamardLaserSpec, 15 Rue Trieux-Scieurs, 5020 Namur, Belgium.
Filip CuyckensDrug Metabolism & Pharmacokinetics, Janssen R&D, Beerse, Belgium.ORCID http://orcid.org/0000-0003-4956-1418
Jos OomensRadboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands. g.berden@science.ru.nl.ORCID http://orcid.org/0000-0002-2717-1278
Giel BerdenRadboud University, Institute for Molecules and Materials, FELIX Laboratory, Toernooiveld 7, 6525 ED Nijmegen, The Netherlands. g.berden@science.ru.nl.ORCID http://orcid.org/0000-0003-1500-922X
Radboud University Nijmegen · NLJanssen (Belgium) · BEUniversity of Namur · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Infrared ion spectroscopy is increasingly recognized as a method to identify mass spectrometry-detected analytes in many (bio)chemical areas and its integration in analytical laboratories is now on the horizon. Commercially available quadrupole ion trap mass spectrometers are attractive ion spectroscopy platforms but operate at relatively high pressures. This promotes collisional deactivation which directly interferes with the multiple-photon excitation process required for ion spectroscopy. To overcome this, infrared lasers having a high instantaneous power are required and therefore a majority of analytical studies have been performed at infrared free electron laser facilities. Proliferation of the technique to routine use in analytical laboratories requires table-top infrared lasers and optical parametric oscillators (OPOs) are the most suitable candidates, offering both relatively high intensities and reasonable spectral tuning ranges. Here, we explore the potential of a range of commercially available high-power OPOs for ion spectroscopy, comparing systems with repetition rates of 10 Hz, 20 kHz, 80 MHz and a continuous-wave (cw) system. We compare the performance for various molecular ions and show that the kHz and MHz repetition-rate systems outperform cw and 10 Hz systems in photodissociation efficiency and offer several advantages in terms of cost-effectiveness and practical implementation in an analytical laboratory not specialized in laser spectroscopy.

Identifiers

PMID34724520
PMCPMC8607882
OpenAlexW3208225375

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.