ArticleOcular oncology and pathology2021
Novel Guarded Needle Trans-Scleral Biopsy for Uveal Melanoma: A Pilot Study.
Article in Ocular oncology and pathology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTrans-scleral biopsy of uveal melanoma (UM) poses an inherent risk of tumor and possibly retinal perforation. We describe a novel technique for trans-scleral biopsy of UM and evaluate its safety and efficacy in an initial cohort of patients.
methodsA retrospective, consecutive observational case series was conducted from October 14, 2019, to April 15, 2020, at Kaiser Permanente, San Francisco, CA among patients with UM of the ciliary body or anterior choroid undergoing trans-scleral fine-needle aspiration biopsy using a novel guarded needle technique.
resultsA total of 6 patients were included in the study, with a mean age of 64.3 (range 35-77) years (5 women 83%). Mean (±SD) tumor thickness and maximal basal diameter were 6.4 (±2.66) and 11.9 (±2.13) mm, respectively. Five out of 6 patients achieved a successful biopsy with reliable gene expression profiling (GEP) results. The only failure to obtain specimen occurred in the first attempted patient and, after a minor technique modification, all subsequent biopsies were successful. No intraoperative or short-term postoperative complications were observed in any patient.
conclusionThis novel trans-scleral biopsy technique appears to be safe and effective when obtaining UM tissue for GEP. This method may provide a more controlled biopsy depth thereby minimizing the risk of tumor perforation and its associated complications while still obtaining adequate biopsy yield.