Evidence map›Paper›PMID 34722162›Full record

ArticleAsia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology2021

Comparison of in vivo kinematics of total knee arthroplasty between cruciate retaining and cruciate substituting insert.

Keiji Iwamoto, Takaharu Yamazaki, Kazuomi Sugamoto, Tetsuya Tomita

Open access · goldAbstract read
In one paragraph

Article in Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Cruciate-substituting and posterior-stabilised total knee arthroplasties had similar gait patterns in the short term.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Keiji IwamotoDepartment of Orthopedic Surgery, National Hospital Organization Osaka National Hospital, Osaka, Japan.
Takaharu YamazakiDepartment of Information Systems, Saitama Institute of Technology, Fukaya, Saitama, Japan.
Kazuomi SugamotoDepartment of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Tetsuya TomitaDepartment of Orthopaedic Biomaterial Science, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Osaka University · JPOsaka National Hospital · JPSaitama Institute of Technology · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe decision to choose cruciate retaining (CR) insert or cruciate substituting (CS) insert during total knee arthroplasty (TKA) remains a controversial issue. We hypothesized that there are different knee kinematics between CR and CS inserts and that a raised anterior lip design would offer a potential minimization of the paradoxical movement and provide joint stability. The objective of this study was to evaluate and compare kinematics of a CR and CS TKA of the same single-radius design.

methodsWe investigated the in vivo knee kinematics of 20 knees with a CR TKA (10 knees in the CR insert and 10 knees in the CS insert). Patients were examined during deep knee flexion using fluoroscopy and femorotibial motion was determined using a 2- to 3-dimensional registration technique, which used computer-assisted design models to reproduce the spatial positions of the femoral and tibial components. We evaluated the knee range of motion (ROM), femoral axial rotation relative to the tibial component, anteroposterior translation, and kinematic pathway of the nearest point of the medial and lateral femoral condyles on the tibial tray.

resultsThe average ROM was 121.0 ± 17.3° in CR and 110.8 ± 12.4° in CS. The amount of femoral axial rotation was 7.2 ± 3.9° in CR, and 7.4 ± 2.7° in CS. No significant difference was observed in the amount of anterior translation between CR and CS. The CR and CS inserts had a similar kinematic pattern up to 100° flexion that was central pivot up to 70° flexion and then paradoxical anterior femoral movement until 100° flexion.

conclusionThe present study demonstrated that there was no significant difference between the inserts in knee kinematics. These kinematic results suggested that the increased anterior lip could not control anterior movement in the CS insert.

Indexed as

2D/3D registrationFluoroscopyIn vivoKinematicsTotal knee arthroplasty

Identifiers

PMID34722162
PMCPMC8521180
OpenAlexW3207849298

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.