Evidence map›Paper›PMID 34719047›Full record

ArticleMagnetic resonance in medicine2022

OxyChip embedded with radio-opaque gold nanoparticles for anatomic registration and oximetry in tissues.

Maciej M Kmiec, Kendra A Hebert, Dan Tse, Sassan Hodge, Benjamin B Williams, Philip E Schaner, Periannan Kuppusamy

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Reconfigurable animal bed-EPR resonator assembly for multimodal co-registration.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
    Article
  5. Computationally efficient 4D spectral-spatial EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025
    Article
  6. Surface dielectric resonator for in vivo EPR measurements.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Maciej M KmiecDepartment of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.
Kendra A HebertDepartment of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.
Dan TseDepartment of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.
Sassan HodgeThayer School of Engineering, Dartmouth College, Hanover, New Hampshire, USA.
Benjamin B WilliamsDepartment of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.
Philip E SchanerDepartment of Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire, USA.
Periannan KuppusamyDepartment of Radiology, Norris Cotton Cancer Center, Geisel School of Medicine, Dartmouth College, Lebanon, New Hampshire, USA.ORCID 0000-0002-3214-0660
Dartmouth College · USDartmouth–Hitchcock Medical Center · US

Funding

Probes and Methods for Clinical OximetryR01EB004031 · NIBIB · OHIO STATE UNIVERSITY · PI KUPPUSAMY, PERIANNAN · 2004 to 2021
$7.1M
Project 3: Direct & Repeated Measurement of pO2 in Deep-seated Tumors using EPR OP01CA190193 · NCI · DARTMOUTH COLLEGE · PI WILLIAMS, BENJAMIN B · 2015 to 2019
$7.0M
NCI NIH HHS P01 CA190193NIBIB NIH HHS R01 EB004031
6 · The paper itself

Abstract

purposeElectron paramagnetic resonance oximetry using the OxyChip as an implantable oxygen sensor can directly and repeatedly measure tissue oxygen levels. A phase I, first-in-human clinical study has established the safety and feasibility of using OxyChip for reliable and repeated measurements of oxygen levels in a variety of tumors and treatment regimens. A limitation in these studies is the inability to easily locate and identify the implanted probes in the tissue, particularly in the long term, thus limiting spatial/anatomical registration of the implant for proper interpretation of the oxygen data. In this study, we have developed and evaluated an enhanced oxygen-sensing probe embedded with gold nanoparticles (GNP), called the OxyChip-GNP, to enable visualization of the sensor using routine clinical imaging modalities.

methodsIn vitro characterization, imaging, and histopathology studies were carried out using tissue phantoms, excised tissues, and in vivo animal models (mice and rats).

resultsThe results demonstrated a substantial enhancement of ultrasound and CT contrast using the OxyChip-GNP without compromising its electron paramagnetic resonance and oxygen-sensing properties or biocompatibility.

conclusionsThe OxyChips embedded with gold nanoparticles (OxyChip-GNP) can be readily identified in soft tissues using standard clinical imaging modalities such as CT, cone beam-CT, or ultrasound imaging while maintaining its capability to make repeated in vivo measurements of tissue oxygen levels over the long term. This unique capability of the OxyChip-GNP facilitates precisely localized in vivo oxygen measurements in the clinical setting.

Indexed as

GoldMetal NanoparticlesAnimalsElectron Spin Resonance SpectroscopyMiceOximetryOxygenRatsGoldOxygenEPRfiducialgold nanoparticlesmedical imagingoximetryOxyChip

Identifiers

PMID34719047
PMCPMC8776570
OpenAlexW3208841102

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.