ArticleAnnals of work exposures and health2022
Comparison of the Analysis of Respirable Crystalline Silica in Workplace Air by Direct-on-Filter Methods using X-ray Diffraction and Fourier Transform Infrared Spectroscopy.
Article in Annals of work exposures and health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 13 citations in OpenAlex.
- A Portable Infrared System for Identification of Particulate Matter.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A comparison of the analysis of respirable crystalline silica direct-on-filter methods using X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy was undertaken using 253 real workplace air samples from road construction and tunnelling, coal mining, and kitchen benchtop manufacturing in Australia. Using pure α-quartz standards, XRD and FT-IR direct-on-filter analyses produced identical test results, however, the real workplace samples showed a clear discrepancy between FT-IR and XRD results with on average a 9% positive bias of the FT-IR results. The cause of the positive bias was due to matrix interferences which was confirmed by using synthetic mixture air samples. Approximately a third of the data by direct-on-filter method using FT-IR was assessed to be invalid based on the peak height ratio criterion due to excessive interferences and weight overload limitations. The XRD method showed better results due to less interference from the common matrices. XRD could handle up to twice the sample loading and at higher loadings up to 7 mg when a correction was applied. It was also able to achieve a lower limit of detection of 2 µg filter-1 when a slower scan condition was utilized.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.