Evidence map›Paper›PMID 34717230›Full record

ArticleComputers in biology and medicine2021

Cerebral aneurysm flow diverter modeled as a thin inhomogeneous porous medium in hemodynamic simulations.

Armin Abdehkakha, Adam L Hammond, Tatsat R Patel, Adnan H Siddiqui, Gary F Dargush, Hui Meng

Abstract read
In one paragraph

Article in Computers in biology and medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Armin AbdehkakhaDepartment of Mechanical & Aerospace Engineering at the University at Buffalo, Buffalo, NY, USA; Canon Stroke and Vascular Research Center at the University at Buffalo, Buffalo, NY, USA.
Adam L HammondDepartment of Mechanical & Aerospace Engineering at the University at Buffalo, Buffalo, NY, USA; Canon Stroke and Vascular Research Center at the University at Buffalo, Buffalo, NY, USA.
Tatsat R PatelDepartment of Mechanical & Aerospace Engineering at the University at Buffalo, Buffalo, NY, USA; Canon Stroke and Vascular Research Center at the University at Buffalo, Buffalo, NY, USA.
Adnan H SiddiquiCanon Stroke and Vascular Research Center at the University at Buffalo, Buffalo, NY, USA; Department of Neurosurgery, Jacobs School of Medicine at the University at Buffalo, Buffalo, NY, USA; Department of Radiology, Jacobs School of Medicine at the University at Buffalo, Buffalo, NY, USA.
Gary F DargushDepartment of Mechanical & Aerospace Engineering at the University at Buffalo, Buffalo, NY, USA.
Hui MengDepartment of Mechanical & Aerospace Engineering at the University at Buffalo, Buffalo, NY, USA; Department of Biomedical Engineering at the University at Buffalo, Buffalo, NY, USA; Canon Stroke and Vascular Research Center at the University at Buffalo, Buffalo, NY, USA. Electronic address: huimeng@buffalo.edu.

Funding

Virtual Intervention of Intracranial AneurysmsR01NS091075 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI MENG, HUI · 2015 to 2019
$1.7M
NINDS NIH HHS R01 NS091075
6 · The paper itself

Abstract

Rapid and accurate simulation of cerebral aneurysm flow modifications by flow diverters (FDs) can help improving patient-specific intervention and predicting treatment outcome. However, when FD devices are explicitly represented in computational fluid dynamics (CFD) simulations, flow around the stent wires must be resolved, leading to high computational cost. Classic porous medium (PM) methods can reduce computational expense but cannot capture the inhomogeneous FD wire distribution once implanted on a cerebral artery and thus cannot accurately model the post-stenting aneurysmal flow. We report a novel approach that models the FD flow modification as a thin inhomogeneous porous medium (iPM). It improves over the classic PM approaches in two ways. First, the FD is more appropriately treated as a thin screen, which is more accurate than the classic 3D-PM-based Darcy-Forchheimer relation. Second, pressure drop is calculated cell-by-cell using the local FD geometric parameters across an inhomogeneous PM. We applied the iPM technique to simulating the post-stenting hemodynamics of three patient-specific aneurysms. To test its accuracy and speed, we compared the results from the iPM technique against CFD simulations with explicit FD devices. The iPM CFD ran 500% faster than the explicit CFD while achieving 94%-99% accuracy; thus, iPM is a promising clinical bedside modeling tool to assist endovascular interventions with FD and stents.

Indexed as

Intracranial AneurysmComputer SimulationHemodynamicsHumansHydrodynamicsPorosityStentsCFD SimulationIntracranial aneurysmPorous mediaStent modelingStent simulation

Identifiers

PMID34717230
PMCPMC9372908

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.