Evidence map›Paper›PMID 34713749›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2022

"Virtual stent" - clinical evaluation and user experience of on-the-fly stent simulation in treatment of cerebral aneurysms.

Hannes Luecking, Annette Birkhold, Philip Hoelter, Stefan Lang, Philipp Goelitz, Manuel Schmidt, Anne Mrochen, Sebastian Brandner, Arnd Doerfler

Open access · greenAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Hannes LueckingDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.ORCID 0000-0002-3935-0003
Annette Birkhold42406Siemens Healthineers AG, Forchheim, Germany.
Philip HoelterDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.ORCID 0000-0001-9768-9630
Stefan LangDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Philipp GoelitzDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Manuel SchmidtDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Anne MrochenDepartment of Neurology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Sebastian BrandnerDepartment of Neurosurgery, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Arnd DoerflerDepartment of Neuroradiology, 9171University of Erlangen-Nuremberg, Erlangen, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DESiemens Healthineers (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPredicting final stent position can be challenging when treating cerebral aneurysms. Third-Party software proved helpful in selecting proper stents in treatment planning. Recent angiographic systems provide basic stent simulation capabilities integrated in the post-processing software to simulate stent position. Goal of this analysis was to evaluate the simulation process and correlation with definite stent position. MATERIALS AND

methodsThirty-three datasets with fusiform (n = 10) and saccular (n = 23) aneurysms, treated with stent or flow-diverter, were processed. A "virtual stent" of the same (nominal) size was simulated and its position was compared to the treatment result. Simulated length was rated in five grades (too short, shorter, equal, longer, too long), with regard to side-branches, anchoring zone etc. Simulation quality (centerline recognition/adherence to vessel margins) was rated in three grades (no, minor or major corrections required).

resultsSimulation was successful in 32/33 cases (97%), with one abortive attempt (3%). In 27/33 simulations (82%), there was no need for centerline refinement. Minor corrections were necessary in four and major corrections in two cases. Simulated nominal length was rated "equal" in 14/33 (42%) cases and "shorter" or "longer" - but within acceptable range - in each 9/33 (27%) cases.

conclusionBasic stent simulation tools available with genuine angiographic workplace software can provide good simulation capabilities without need for third-party equipment. They can facilitate treatment planning and help to avoid shortage of devices. Yet, lack of calculation of foreshortening in large vessel diameters leaves the user to rely on their experience to account for device-specific properties.

Indexed as

Intracranial AneurysmAngiographyCerebral AngiographyComputer SimulationHumansStentsTreatment Outcomecerebral aneurysmflat panel ctstent simulationvirtual stent

Identifiers

PMID34713749
PMCPMC9511612
OpenAlexW3211214189

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.