Evidence map›Paper›PMID 34713653›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2021

[Structural design and biomechanical numerical analysis of body-fitted stent in stenotic vessels].

Sicong Liu, Hanbing Zhang, Xiao Li, Ning Liu, Aike Qiao

Abstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. [Numerical study on structural design and mechanical analysis of anti-migration tracheal stent with non-uniform Poisson's ratio].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
  3. [Structural design of "fitness" and "feasibility" of body-fitted stent and its mechanical analysis].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sicong LiuDepartment of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China.
Hanbing ZhangDepartment of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China.
Xiao LiDepartment of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China.
Ning LiuDepartment of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China.
Aike QiaoDepartment of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing 100124, P.R.China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To solve the problem of stent malapposition of intravascular stents, explore the design method of intravascular body-fitted stent structure and to establish an objective apposition evaluation method, the support and apposition performance of body-fitted stent in the stenotic vessels with different degrees of calcified plaque were simulated and analyzed. The traditional tube-mesh-like stent model was constructed by using computational aided design tool SolidWorks, and based on this model, the body-fitted stent model was designed by means of projection algorithm. Abaqus was used to simulate the crimping-expansion-recoil process of the two stents in the stenotic vessel with incompletely calcified plaque and completely calcified plaque respectively. A comprehensive method for apposition evaluation was proposed considering three aspects such as separation distance, fraction of non-contact area and residual volume. Compared with the traditional stent, the separation distances of the body-fitted stent in the incompletely calcified plaque model and the completely calcified plaque model were decreased by 21.5% and 22.0% respectively, the fractions of non-contact areas were decreased by 11.3% and 11.1% respectively, and the residual volumes were decreased by 93.1% and 92.5% respectively. The body-fitted stent improved the apposition performance and was effective in both incompletely and completely calcified plaque models. The established apposition performance evaluation method of stent considered more geometric factors, and the results were more comprehensive and objective.

Indexed as

Plaque, AtheroscleroticStentsConstriction, PathologicHumansarterial stenosisbiomechanicsendovascular stentnumerical simulationstent malapposition

Identifiers

PMID34713653
PMCPMC9927437

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.