Evidence map›Paper›PMID 34709193›Full record

ArticleJournal of medical Internet research2021

Improved Environment-Aware-Based Noise Reduction System for Cochlear Implant Users Based on a Knowledge Transfer Approach: Development and Usability Study.

Lieber Po-Hung Li, Ji-Yan Han, Wei-Zhong Zheng, Ren-Jie Huang, Ying-Hui Lai

Abstract read
In one paragraph

Article in Journal of medical Internet research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Progress made in the efficacy and viability of deep-learning-based noise reduction.The Journal of the Acoustical Society of America · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Lieber Po-Hung LiDepartment of Otolaryngology, Cheng Hsin General Hospital, Taipei, Taiwan.ORCID 0000-0003-4799-4105
Ji-Yan HanDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.ORCID 0000-0001-9208-8502
Wei-Zhong ZhengDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.ORCID 0000-0002-4993-2541
Ren-Jie HuangDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.ORCID 0000-0003-1386-5452
Ying-Hui LaiDepartment of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan.ORCID 0000-0003-4120-7289

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCochlear implant technology is a well-known approach to help deaf individuals hear speech again and can improve speech intelligibility in quiet conditions; however, it still has room for improvement in noisy conditions. More recently, it has been proven that deep learning-based noise reduction, such as noise classification and deep denoising autoencoder (NC+DDAE), can benefit the intelligibility performance of patients with cochlear implants compared to classical noise reduction algorithms.

objectiveFollowing the successful implementation of the NC+DDAE model in our previous study, this study aimed to propose an advanced noise reduction system using knowledge transfer technology, called NC+DDAE_T; examine the proposed NC+DDAE_T noise reduction system using objective evaluations and subjective listening tests; and investigate which layer substitution of the knowledge transfer technology in the NC+DDAE_T noise reduction system provides the best outcome.

methodsThe knowledge transfer technology was adopted to reduce the number of parameters of the NC+DDAE_T compared with the NC+DDAE. We investigated which layer should be substituted using short-time objective intelligibility and perceptual evaluation of speech quality scores as well as t-distributed stochastic neighbor embedding to visualize the features in each model layer. Moreover, we enrolled 10 cochlear implant users for listening tests to evaluate the benefits of the newly developed NC+DDAE_T.

resultsThe experimental results showed that substituting the middle layer (ie, the second layer in this study) of the noise-independent DDAE (NI-DDAE) model achieved the best performance gain regarding short-time objective intelligibility and perceptual evaluation of speech quality scores. Therefore, the parameters of layer 3 in the NI-DDAE were chosen to be replaced, thereby establishing the NC+DDAE_T. Both objective and listening test results showed that the proposed NC+DDAE_T noise reduction system achieved similar performances compared with the previous NC+DDAE in several noisy test conditions. However, the proposed NC+DDAE_T only required a quarter of the number of parameters compared to the NC+DDAE.

conclusionsThis study demonstrated that knowledge transfer technology can help reduce the number of parameters in an NC+DDAE while keeping similar performance rates. This suggests that the proposed NC+DDAE_T model may reduce the implementation costs of this noise reduction system and provide more benefits for cochlear implant users.

Indexed as

Cochlear ImplantationCochlear ImplantsSpeech PerceptionHumansNoiseSpeech Intelligibilityaudiocochlearcochlear implantsdeafdeep learninghearingnoise classificationnoise reductionsound

Identifiers

PMID34709193
PMCPMC8587190

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.