Evidence map›Paper›PMID 34708544›Full record

ArticleActa ophthalmologica2022

Effects of glaucoma surgery on visual field progression in open-angle glaucoma considering the floor effect.

Andreas Schlatter, Teresa Rauchegger, Eduard Schmid, Barbara Teuchner

Open access · hybridAbstract read
In one paragraph

Article in Acta ophthalmologica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Andreas SchlatterDepartment of Ophthalmology and Optometry, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, 6020, Austria.ORCID https://orcid.org/0000-0003-2157-2203
Teresa RaucheggerDepartment of Ophthalmology and Optometry, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, 6020, Austria.ORCID https://orcid.org/0000-0003-3439-6333
Eduard SchmidDepartment of Ophthalmology and Optometry, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, 6020, Austria.
Barbara TeuchnerDepartment of Ophthalmology and Optometry, Medical University of Innsbruck, Anichstrasse 35, Innsbruck, 6020, Austria.
Innsbruck Medical University · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this retrospective analysis was to investigate whether trabeculectomy (TRAB) and XEN® Gel Stent implantation (XEN) - both filtrating surgery techniques - can slow down the deterioration of visual field (VF) parameters considering the floor effect, which could lead to a misestimation of pre- and postoperative VF rate of progression (ROP).

methodsIncluded in this study were patients with open-angle glaucoma, who underwent either TRAB or XEN® gel stent implantation and who had at least three VF tests before and after surgery, over an observation period of 13 years. The annual ROP of the mean defect (MD) and the square root of loss variance (sLV) were calculated with two different censoring thresholds: by censored regression and by ordinary least squares regression (OLSR). In addition, the diagnostic range of sLV was calculated.

results48 eyes of 39 glaucoma patients were included in the study. The annual rate of MD progression was significantly reduced by filtering surgery when calculating the yearly ROP using OLSR (p = 0.006) and by censoring values exceeding a precalculated cut-off of 14.20 dB (p = 0.041) and a cut-off from the literature of 15.00 dB (p = 0.028). On average, the MD was impacted by a significant floor effect of 14.20 dB (95% CI: 12.83-15.56), corresponding to 17.7/59 absolute defects or 29.9% of the whole VF. When applying both OLSR and censored regression, the annual rate of sLV progression did not show a significant difference. The sLV showed a diagnostic boundary at a MD of 15.78 dB.

conclusionThis study shows that filtering surgery can reduce the progression of VF in patients with open-angle glaucoma, especially those whose disease develops aggressively. This is valid even if the floor effect in advanced cases is compensated by censored regression. On average, the ROP of MD is affected by a significant floor effect at about 29.9% absolute loss of the whole VF.

Indexed as

GlaucomaGlaucoma, Open-AngleDisease ProgressionHumansIntraocular PressureRetrospective StudiesVisual FieldsVisual Field Testscensored regressionfloor effectglaucoma surgerytrabeculectomyvisual fieldXEN Gel Stent

Identifiers

PMID34708544
PMCPMC9544081
OpenAlexW3209504442

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.