Evidence map›Paper›PMID 34704417›Full record

ArticleZhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences2021

Application of genetic screening processor in screening neonatal glucose-6-phosphate dehydrogenase deficiency.

Haixia Miao, Yu Zhang, Kexin Fang, Yezhen Shi, Ting Zhang, Rongqing Chen, Dingwen Wu, Rulai Yang, Xinwen Huang

Abstract read
In one paragraph

Article in Zhejiang da xue xue bao. Yi xue ban = Journal of Zhejiang University. Medical sciences, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Haixia Miao2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Yu Zhang2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Kexin Fang2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Yezhen Shi2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Ting Zhang2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Rongqing Chen2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Dingwen Wu2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Rulai Yang2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.
Xinwen Huang2. Zhejiang Biosan Biochemical Technology Co., Ltd., Hangzhou 310012, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To evaluate the performance of genetic screening processor (GSP analyzer) in neonatal screening for glucose-6-phosphate dehydrogenase (G6PD)deficiency. The accuracy and precision of GSP analyzer was evaluated with the control materials from National Center for Clinical Laboratories and the low and high quality G6PD control kit (fluorescence analysis). GSP analyzer and semi-automatic fluorescence immunoanalyzer (1420 analyzer) were simultaneously used to detect 2622 neonatal screening samples and 41 confirmed samples to analyze the correlation and consistency of the test results; 78 floating samples and 78 non-floating samples were detected to compare the result. A total of 1 100 384 neonatal screening samples from January 2017 to December 2018 and 855 856 neonatal screening samples from January 2019 to December 2020 were detected with 1420 analyzer and GSP analyzer, respectively. Referring to the percentile method and the expert consensus, the new cut-off value of GSP analyzer for G6PD deficiency in screening was established. The relative bias of GSP analyzer in detecting G6PD was 0.71%-4.23%; the intra assay precision was 4.34%-4.91%, the inter assay precision was 0.85%-2.12%, and the total coefficient of variation was 5.44%-5.72%. There was a significant positive correlation between G6PD activity detected by GSP analyzer and 1420 analyzer (=0.740, <0.01). Forty-one clinical confirmed patients were identified by both 1420 analyzer and GSP analyzer (=0.945). The G6PD activity in floating dry blood spots detected by 1420 analyzer was significantly lower than that in non-floating dry blood spots (<0.05), but there was no significant difference in G6PD activity between floating and non-floating dry blood spots detected by GSP analyzer (>0.05). The sensitivities of GSP analyzer and 1420 analyzer in screening G6PD deficiency were both 100.00%, and the specificities were both more than 99.80%. Compared with 1420 analyzer, the positive predictive value, positive rate and prevalence of G6PD deficiency detected by GSP analyzer were increased, and the false positive rate was decreased (all <0.01). The new cut-off value was 26.1 U/dL for male and 29.1 U/dL for female according to the 99.1% percentile of the population. GSP analyzer has better detection performance with high automation, efficiency and throughput, which can be used in large-scale screening for neonatal G6PD deficiency.

Indexed as

Glucosephosphate Dehydrogenase DeficiencyFemaleGenetic TestingGlucosephosphate DehydrogenaseHumansInfant, NewbornMaleNeonatal ScreeningPredictive Value of TestsGlucosephosphate DehydrogenaseCut-off valueFluorescence immunoassayGlucose-6-phosphate dehydrogenase deficiencyNeonatal screening

Identifiers

PMID34704417
PMCPMC8714485

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.