Evidence map›Paper›PMID 34704144›Full record

ArticleInternational orthopaedics2022

Biomechanical study on the stability and strain conduction of intertrochanteric fracture fixed with proximal femoral nail antirotation versus triangular supporting intramedullary nail.

Haicheng Wang, Weijie Yang, Kai Ding, Yanbin Zhu, Yifan Zhang, Chuan Ren, Kuo Zhao, Qi Zhang, Wei Chen, Yingze Zhang

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 15 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Risk factors for preoperative deep venous thrombosis in hip fracture patients: a meta-analysis.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2022
    Pooled it
  4. Article
  5. Article
  6. Review
  7. Article
  8. Efficacy of poller screw in addition to lag screw in the treatment of intertrochanteric fractures with proximal femoral nail: a biomechanical evaluation.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Haicheng WangDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Weijie YangDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Kai DingDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Yanbin ZhuDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Yifan ZhangDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Chuan RenDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Kuo ZhaoDepartment of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
Qi Zhang *Department of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China. drzhangqi1@163.com.
Wei Chen *Department of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China. surgeonchenwei@126.com.ORCID http://orcid.org/0000-0001-5451-6430
Yingze Zhang *Department of Orthopaedic Surgery, The 3Rd Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesBased on the features of the three-dimensional spatial structure of the proximal femoral trabeculae, we developed a bionic triangular supporting intramedullary nail (TSIN) for the treatment of the femoral intertrochanteric fracture. The current study aimed to compare the mechanical stability and restoration of mechanical conduction between proximal femoral nail antirotation (PFNA) and TSIN to fix the intertrochanteric fractures.

methodsFirstly, five sets of PFNA and TSIN with the same size were selected and fixed on a biomechanical testing machine, and strain gauges were pasted on the main nail, lag screw, and supporting screw to load to the vertical load to 600 N, and the displacement and strain values were recorded. Secondly, formalin-preserved femurs were selected, and the left and right femurs of the same cadaver were randomly divided into two groups to prepare intertrochanteric femur fractures (AO classification 31-A1), which were fixed with PFNA (n = 15) and TSIN (n = 15), respectively. Sixteen sites around the fracture line were chosen to paste strain gauges and loaded vertically to 600 N, and then, the fracture fragment displacement and strain values were recorded. Finally, a 10,000-cycle test ranging from 10 to 600 N was conducted, and the cycle number and displacement value were recorded.

resultsThe overall displacement of PFNA was 2.17 ± 0.18 mm, which was significantly greater than the displacement of the TSIN group (1.66 ± 0.05 mm, P < 0.05) under a vertical load of 600 N. The strain below the PFNA lag screw was 868.29 ± 147.85, which was significantly greater than that of the TSIN (456.02 ± 35.06, P < 0.05); the strain value at the medial side of the PFNA nail was 444.00 ± 34.23, which was significantly less than that of the TSIN (613.57 ± 108.00, P < 0.05). Under the vertical load of 600 N, the displacement of the fracture fragments of the PFNA group was 0.95 ± 0.25 mm, which was significantly greater than that of the TSIN group (0.41 ± 0.09 mm, P < 0.05). The femoral specimens in the PFNA group showed significantly greater strains at the anterior (1, 2, and 4), lateral (7, 9, and 10), posterior (11), and medial (15 and 16) sites than those in the TSIN group (all P < 0.05). In the cyclic compression experiment, the displacements of the PFNA group at 2000, 4000, 6000, 8000, and 10,000 cycles were 1.38 mm, 1.81 mm, 2.07 mm, 2.64 mm, and 3.58 mm, respectively, which were greater than the corresponding displacements of the TSIN group: 1.01 mm, 1.48 mm, 1.82 mm, 2.05 mm, and 2.66 mm (P

conclusionsThe current study showed that TSIN had apparent advantages in stability and stress conduction. TSIN enhanced the stability of intertrochanteric fractures, particularly in superior fracture fragments, improved stress conduction, reduced the stress in the anterior and medial femur, and restored the biomechanical properties of the femur.

Indexed as

Fracture Fixation, IntramedullaryHip FracturesBiomechanical PhenomenaBone NailsFemurHumansTreatment OutcomeBiomechanicsFractureIntertrochanteric fractureIntramedullary fixationProximal femurTriangular supporting intramedullary nail

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.