Evidence map›Paper›PMID 34702894›Full record

ArticleScientific reports2021

Stereotactic navigation versus ultrasound guidance in placing IRE applicators in a liver phantom.

David Stillström, Benjamin Eigl, Jacob Freedman

Abstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

David StillströmDivision of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden. david.stillstrom@ki.se.ORCID 0000-0003-1281-3095
Benjamin EiglCASCINATION AG, Bern, Switzerland.
Jacob FreedmanDivision of Surgery, Department of Clinical Sciences, Karolinska Institutet at Danderyd Hospital, Stockholm, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to compare the accuracy of stereotactic CT-guided navigation and ultrasound guided navigation for placing electrodes in Irreversible electroporation in a liver phantom. A liver phantom with multiple tumours was used and interventionists placed four IRE electrodes around each tumour guided either by stereotactic CT-guided navigation or ultrasound. The goal was to place them in a perfect 20 × 20 mm square with parallel electrodes. After each treatment, a CT-scan was performed. The accuracy in pairwise electrode distance, pairwise parallelism and time per tumour was analysed. Eight interventionists placed four electrodes around 55 tumours, 25 with ultrasound and 30 with stereotactic CT-guided navigation. 330 electrode pairs were analysed, 150 with ultrasound and 180 with stereotactic CT-navigation. The absolute median deviation from the optimal distance was 1.3 mm (range 0.0 to 11.3 mm) in the stereotactic CT-navigation group versus 7.1 mm (range 0.3 to 18.1 mm) in the Ultrasound group (p < 0.001). The mean angle between electrodes in each pair was 2.7 degrees (95% CI 2.4 to 3.1 degrees) in the stereotactic CT-navigation group and 5.5 degrees (95% CI 5.0 to 6.1 degrees) in the Ultrasound group (p < 0.001). The mean time for placing the electrodes was 15:11 min (95% CI 13:05 to 17:18 min) in the stereotactic CT-navigation group and 6:40 min (95% CI 5:28 to 7:52 min) in the Ultrasound group. The use of stereotactic CT-navigation in placing IRE-electrodes in a liver phantom is more accurate, but more time consuming, compared to ultrasound guidance.

Indexed as

LiverPhantoms, ImagingSurgery, Computer-AssistedElectrodesHumansTomography, X-Ray ComputedUltrasonography

Identifiers

PMID34702894
PMCPMC8548523

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.