Evidence map›Paper›PMID 34702795›Full record

Observational studyMedical science monitor : international medical journal of experimental and clinical research2021

Accuracy of Continuous and Noninvasive Hemoglobin Monitoring in the Presence of CO2 Insufflation: An Observational Pilot Study.

Hye Sun Lee, Ji Won Yoo, Ha Yeon Kim, Na Young Kim, Ji Eun Kim

Open access · hybridAbstract readObservational Study
In one paragraph

Observational study in Medical science monitor : international medical journal of experimental and clinical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Hye Sun LeeBiostatistics Collaboration Unit, Yonsei University College of Medicine, Seoul, South Korea.ORCID 0000-0001-6328-6948
Ji Won YooDepartment of Internal Medicine, University of Nevada Las Vegas School of Medicine, Las Vegas, NV, USA.ORCID 0000-0001-7196-8682
Ha Yeon KimDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, South Korea.
Na Young KimDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, South Korea.
Ji Eun KimDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, South Korea.
Ajou University · KRUniversity of Nevada, Las Vegas · USYonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Laparoscopic surgery has several benefits, but it requires prolonged carbon dioxide (CO₂) insufflation. Several factors affect the accuracy of continuous and noninvasive hemoglobin (SpHb) monitoring, but the effects of CO₂ insufflation are undetermined. This study investigated the effect of CO₂ insufflation on SpHb monitoring in laparoscopic surgery. MATERIAL AND METHODS Twenty patients undergoing laparoscopic gastrectomy were enrolled. Anesthesia was maintained using sevoflurane and remifentanil within an end-tidal CO₂ of 30-45 mmHg. The CO₂ insufflation was maintained at 12 mmHg using CO₂. SpHb was monitored with a Radical-7 Pulse CO-Oximeter, and laboratory hemoglobin (tHb) was analyzed using a satellite blood analyzer. RESULTS Forty paired measurements were analyzed. The mean perfusion index, SpHb, and tHb were 3.10±1.77%, 10.92±1.48 g/dL, and 11.51±0.88 g/dL, respectively. SpHb underestimated tHb with a bias (precision) of -0.59 (1.28 g/dL), and the 95% limit of agreement was wide (-3.11 to 1.92 g/dL). SpHb was moderately correlated with tHb (r=0.50, 95% CI: 0.23 to 0.70). The concordance rate was 67%. ΔSpHb was not correlated with ΔtHb (r=0.29, 95% CI: -0.18 to -0.65). A similar bias, wider limits of agreement, a higher |SpHb-tHb|, but more significant correlation between SpHb and tHb were observed for the "PaCO2 <40 mmHg" range compared with the "40 mmHg ≤PaCO₂" range. CONCLUSIONS SpHb may have an acceptable accuracy but has a weak trending ability in the presence of CO₂ insufflation, and it can be affected by PaCO₂. Further research on the effects of CO₂ insufflation on SpHb is needed.

Indexed as

AgedCarbon DioxideFemaleHemoglobinsHumansInsufflationLaparoscopyMaleMiddle AgedMonitoring, IntraoperativePilot ProjectsCarbon DioxideHemoglobins

Identifiers

PMID34702795
PMCPMC8559297
OpenAlexW3195114148

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.