Evidence map›Paper›PMID 34702640›Full record

ArticleUltrasound in medicine & biology2022

Occult Regions of Suppressed Coherence in Liver B-Mode Images.

Katelyn Offerdahl, Matthew Huber, Will Long, Nick Bottenus, Rendon Nelson, Gregg Trahey

Open access · greenAbstract read
In one paragraph

Article in Ultrasound in medicine & biology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Katelyn OfferdahlDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, USA. Electronic address: kro18@duke.edu.
Matthew HuberDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
Will LongDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
Nick BottenusDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado, USA.
Rendon NelsonDepartment of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
Gregg TraheyDepartment of Biomedical Engineering, Duke University, Durham, North Carolina, USA; Department of Radiology, Duke University Medical Center, Durham, North Carolina, USA.
Duke University · USDuke Medical Center · US

Funding

Coherence-Based Fetal Ultrasonic ImagingR01EB017711 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2014 to 2025
$4.7M
A Patient-Adaptive, High MI Abdominal ScannerR01EB026574 · NIBIB · DUKE UNIVERSITY · PI TRAHEY, GREGG E. · 2018 to 2021
$2.3M
NIBIB NIH HHS R01 EB017711NIBIB NIH HHS R01 EB026574
6 · The paper itself

Abstract

Ultrasound is an essential tool for diagnosing and monitoring diseases, but it can be limited by poor image quality. Lag-one coherence (LOC) is an image quality metric that can be related to signal-to-noise ratio and contrast-to-noise ratio. In this study, we examine matched LOC and B-mode images of the liver to discern patterns of low image quality, as indicated by lower LOC values, occurring beneath the abdominal wall, near out-of-plane vessels and adjacent to hyperechoic targets such the liver capsule. These regions of suppressed coherence are often occult; they present as temporally stable uniform speckle on B-mode images, but the LOC measurements in these regions suggest substantially degraded image quality. Quantitative characterization of the coherence suppression beneath the abdominal wall reveals a consistent pattern both in simulations and in vivo; sharp drops in coherence occurring beneath the abdominal wall asymptotically recover to a stable coherence at depth. Simulation studies suggest that abdominal wall reverberation clutter contributes to the initial drop in coherence but does not influence the asymptotic LOC value. Clinical implications are considered for contrast loss in B-mode imaging and estimation errors for elastography and Doppler imaging.

Indexed as

Image Processing, Computer-AssistedLiverPhantoms, ImagingSignal-To-Noise RatioUltrasonographyClutterCoherenceImage qualityLag-one coherenceLiver imagingSpatial coherence

Identifiers

PMID34702640
PMCPMC9969659
OpenAlexW3210292233

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.