ArticleTurkish journal of ophthalmology2021
The Surgeon's Role in Inducing and Controlling Motion Errors During Intraocular Membrane Peeling Procedures
Article in Turkish journal of ophthalmology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objectives: To understand the surgeon's role in inducing and correcting movement inaccuracies during intraocular membrane peeling procedures. Materials and Methods: Optical sensors were used to record movement errors during actuation at the distal tip of 23-gauge pneumatic forceps both when the handle was handheld and when fixed with no human contact. Movements were also recorded at the proximal part of the forceps shaft (near the sclerotomy site) and compared to movement recorded at the distal end. The root mean square (RMS) and range values of the signals obtained from the sensors were calculated before and after applying high (7-13 Hz) and low (<5 Hz) frequency filters. Results: Comparison of RMS and range values of movement errors at the distal end of the forceps during actuation when the forceps handle was fixed and handheld showed that without human contact, these values were significantly lower in the X axis at all frequencies and in the Z axis at high frequencies compared to handheld (p<0.05), while there were no significant differences in the Y axis. Comparison of values from the distal and proximal ends of the forceps showed that when the forceps were fixed, RMS and range values were significantly higher for movement errors at the distal end compared to the proximal end at all frequencies (p<0.05). There was significant positive correlation between the extent of actuation and the RMS and range values for high-frequency movement errors but not low-frequency errors in all three axes with the fixed pneumatic handle (r=0.21-0.51, p<0.05). Conclusion: Surgeon- and non-surgeon-related errors are apparent in all axes, but skilled surgeons correct these errors through visual feedback, resulting in better correction in the visible planes. Sclerotomy sites provide a pivoting and stabilizing point for the shaft of the forceps and it is likely that skilled surgeons make use of the sclerotomy point to dampen motion errors, a skill worth teaching to beginners.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.