ArticleJournal of applied clinical medical physics2021
A novel CRT-IMRT-combined (Co-CRIM) planning technique for peripheral lung stereotactic body radiotherapy in pinnacle treatment planning system.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 5 citations in OpenAlex.
- Comparison of dosimetric parameters and delivery accuracy between conformal radiotherapy-intensity modulated radiotherapy-combined and intensity-modulated radiotherapy planning for central lung cancer patients receiving stereotactic body radiotherapy.Quantitative imaging in medicine and surgery · 2026Article
- Artificial Intelligence in Lung Cancer: A Narrative Review of Recent Advances in Diagnosis, Biomarker Discovery, and Drug Development.Pharmaceutics · 2026Review
- Optimizing lung SBRT delivery: A hybrid approach combining dynamic conformal arc (DCA) and volumetric modulated arc therapy (VMAT) techniques.Journal of applied clinical medical physics · 2025Article
- A novel CRT-IMRT-combined (Co-CRIM) planning technique for peripheral lung stereotactic body radiotherapy in pinnacle treatment planning system.Journal of applied clinical medical physics · 2021Article
- Voxel-Level BED Corrected Dosimetric and Radiobiological Assessment of 2 Kinds of Hybrid Radiotherapy Planning Methods for Stage III NSCLC.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 6 institutions in 3 countries.
Funding
Abstract
objectivesThis study attempts to explore a novel peripheral lung stereotactic body radiotherapy (SBRT) planning technique that can balance the pros and cons of three-dimensional conformal radiotherapy (CRT) and intensity-modulated radiation therapy (IMRT) / volumetric modulated arc therapy (VMAT).
methodsTreatment plans were retrospectively designed based on CRT, IMRT, VMAT, and the proposed CRT-IMRT-combined (Co-CRIM) techniques using Pinnacle treatment planning system (TPS) for 20 peripheral lung cancer patients. Co-CRIM used an inverse optimization algorithm available in Pinnacle TPS. To develop a Co-CRIM plan, the number of segments in each field was limited to one, the minimum segment area was set to the internal target volume (ITV), and the minimum monitor units (MU) of the segment was the quotient of fractional dose divided by twice the number of total fields. The performance of Co-CRIM was then compared with other techniques.
resultsFor conformity index (CI), Co-CRIM performed comparably to IMRT/VMAT but better than CRT. For gradient index (GI), Co-CRIM was similar to IMRT/VMAT or CRT. For heterogeneity index (HI), Co-CRIM was comparable to IMRT/VMAT, higher than CRT. The dosimetric results of spinal cord and lung with Co-CRIM were better than CRT, comparable to IMRT, but inferior to VMAT. The MU resulted from Co-CRIM was lower than IMRT/VMAT but higher than CRT. For plan verification γ passing rate, Co-CRIM was higher than IMRT/VMAT, comparable to CRT. For planning time, Co-CRIM was shorter than CRT or VMAT but similar to IMRT.
conclusionsThe proposed Co-CRIM technique on Pinnacle TPS is an effective planning technique for peripheral lung SBRT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.