Evidence map›Paper›PMID 34694729›Full record

ArticleIET nanobiotechnology2021

On-chip label-free impedance-based detection of antibiotic permeation.

Jaspreet Kaur, Hamed Ghorbanpoor, Yasin Öztürk, Özge Kaygusuz, Hüseyin Avcı, Cihan Darcan, Levent Trabzon, Fatma D Güzel

Open access · goldAbstract read
In one paragraph

Article in IET nanobiotechnology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 19 citations in OpenAlex.

  1. Review
  2. Article
  3. Nano-biotechnology in tumour and cancerous disease: A perspective review.Journal of cellular and molecular medicine · 2023
    Review
  4. On chip microfluidic separation of cyclotides.Turkish journal of chemistry · 2023
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

Jaspreet KaurDepartment of Electrical and Electronic Engineering, Yıldırım Beyazıt University, Ankara, Turkey.ORCID https://orcid.org/0000-0002-2883-9241
Hamed GhorbanpoorDepartment of Biomedical Engineering, Yıldırım Beyazıt University, Ankara, Turkey.
Yasin ÖztürkDepartment of Material Engineering, Yıldırım Beyazıt University, Ankara, Turkey.
Özge KaygusuzBiotechnology Application and Research Center, Bilecik Şeyh Edebali University, Bilecik, Turkey.
Hüseyin AvcıMetallurgical and Materials Engineering Department, Eskisehir Osmangazi University, Eskisehir, Turkey.
Cihan DarcanBiotechnology Application and Research Center, Bilecik Şeyh Edebali University, Bilecik, Turkey.
Levent TrabzonDepartment of Mechanical Engineering, Istanbul Technical University, Istanbul, Turkey.
Fatma D GüzelDepartment of Biomedical Engineering, Yıldırım Beyazıt University, Ankara, Turkey.
Ankara Yıldırım Beyazıt University · TRBilecik Şeyh Edebali Üniversitesi · TREskişehir Osmangazi University · TRIstanbul Technical University · TR

Funding

TUBITAK 217M151
6 · The paper itself

Abstract

Biosensors are analytical tools used for the analysis of biomaterial samples and provide an understanding about the biocomposition, structure, and function of biomolecules and/or biomechanisms by converting the biological response into an electrical and/or optical signal. In particular, with the rise in antibiotic resistance amongst pathogenic bacteria, the study of antibiotic activity and transport across cell membranes in the field of biosensors has been gaining widespread importance. Herein, for the rapid and label-free detection of antibiotic permeation across a membrane, a microelectrode integrated microfluidic device is presented. The integrated chip consists of polydimethylsiloxane based microfluidic channels bonded onto microelectrodes on-glass and enables us to recognize the antibiotic permeation across a membrane into the model membranes based on electrical impedance measurement, while also allowing optical monitoring. Impedance testing is label free and therefore allows the detection of both fluorescent and non-fluorescent antibiotics. As a model membrane, Giant Unilamellar Vesicles (GUVs) are used and impedance measurements were performed by a precision inductance, capacitance, and resistance metre. The measured signal recorded from the device was used to determine the change in concentration inside and outside of the GUVs. We have found that permeation of antibiotic molecules can be easily monitored over time using the proposed integrated device. The results also show a clear difference between bilayer permeation that occurs through the lipidic bilayer and porin-mediated permeation through the porin channels inserted in the lipid bilayer.

Indexed as

Anti-Bacterial AgentsMicrofluidic Analytical TechniquesElectric ImpedanceLab-On-A-Chip DevicesLipid BilayersAnti-Bacterial AgentsLipid Bilayers

Identifiers

PMID34694729
PMCPMC8675796
OpenAlexW3126642352

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.