ArticleMikrochimica acta2021
A paper-based polystyrene/nylon Janus platform for the microextraction of UV filters in water samples as proof-of-concept.
Article in Mikrochimica acta, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Environmental Fate of 4-Methylbenzylidene Camphor: Adsorption Behavior on Textile-Derived Microplastic Fibers in Wastewater and Surface Water Systems.Materials (Basel, Switzerland) · 2025Article
- Single-fibre coating and additive manufacturing of multifunctional papers.RSC advances · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
A new mix-mode cellulose-based sorptive phase is described that combines two different polymeric domains (i.e., nylon and polystyrene), thus providing simultaneous hydrophilic and hydrophobic features as a result. By analogy with Janus materials, the new paper-based sorptive phase has been named paper-based polystyrene/nylon Janus-platform (P-Ps/Ny-JP). The main advantages of the proposed P-Ps/Ny-JP are the sustainability, simplicity in synthesis, and low cost of this extraction device. The main parameters affecting the synthesis (i.e., coating procedure and polymers proportion) have been studied, and the resulting material has been characterized via scanning electron microscopy and infrared spectroscopy. As a proof-of-concept, the simultaneous extraction of fourteen UV filters of a wide range of polarity, with log P values ranging from - 0.234 to 16.129, from water samples and their determination by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been performed. The proposed methodology enables the determination of these chemicals with limits of detection from 12 to 71 ng L
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.