ArticleACS omega2021
Large-Scale, Cuttable, Full Tissue-Based Capacitive Pressure Sensor for the Detection of Human Physiological Signals and Pressure Distribution.
Article in ACS omega, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Facile Fabrication of a Highly Sensitive and Robust Flexible Pressure Sensor with Batten Microstructures.Micromachines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The increasing demand for flexible and wearable electronics has promoted the rapid development of the pressure sensors capable of monitoring diverse human movements and physiological signals. However, more and more research requires the pressure sensor to possess high sensing performance and desires the fabrication to exhibit the characteristics of low cost, large-scale production, high reproduction, even disposability. Here, we propose a full tissue-based capacitive pressure sensor with a sandwiched structure consisting of two MXene-coated tissue electrodes and a blank tissue dielectric layer. The tight contact and adequate adsorption of the MXene sheets with the cellulose fibers endow the electrode with uniform conductivity and high stability over a large area. In addition, the flexible sensor could be conveniently cut into any shape and size to meet the diverse application requirements. Thereby, the pressure sensor exhibits a sensitivity of 0.051 kPa
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.