Evidence map›Paper›PMID 34690682›Full record

ArticleFrontiers in neuroscience2021

Patients Prefer a Virtual Reality Approach Over a Similarly Performing Screen-Based Approach for Continuous Oculomotor-Based Screening of Glaucomatous and Neuro-Ophthalmological Visual Field Defects.

Rijul Saurabh Soans, Remco J Renken, James John, Amit Bhongade, Dharam Raj, Rohit Saxena, Radhika Tandon, Tapan Kumar Gandhi, Frans W Cornelissen

Abstract read
In one paragraph

Article in Frontiers in neuroscience, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Diagnostic performance of pupil perimetry in detecting hemianopia under standard and virtual reality viewing conditions.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Article
  6. Review
  7. Pilot study comparing a new virtual reality-based visual field test to standard perimetry in children.Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2024
    Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Rijul Saurabh SoansDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi, India.
Remco J RenkenDepartment of Biomedical Sciences of Cells and Systems, Cognitive Neuroscience Center, University Medical Center Groningen, University of Groningen, Groningen, Netherlands.
James JohnDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi, India.
Amit BhongadeDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi, India.
Dharam RajDepartment of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Rohit SaxenaDepartment of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Radhika TandonDepartment of Ophthalmology, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Tapan Kumar GandhiDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi, India.
Frans W CornelissenLaboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Standard automated perimetry (SAP) is the gold standard for evaluating the presence of visual field defects (VFDs). Nevertheless, it has requirements such as prolonged attention, stable fixation, and a need for a motor response that limit application in various patient groups. Therefore, a novel approach using eye movements (EMs) - as a complementary technique to SAP - was developed and tested in clinical settings by our group. However, the original method uses a screen-based eye-tracker which still requires participants to keep their chin and head stable. Virtual reality (VR) has shown much promise in ophthalmic diagnostics - especially in terms of freedom of head movement and precise control over experimental settings, besides being portable. In this study, we set out to see if patients can be screened for VFDs based on their EM in a VR-based framework and if they are comparable to the screen-based eyetracker. Moreover, we wanted to know if this framework can provide an effective and enjoyable user experience (UX) compared to our previous approach and the conventional SAP. Therefore, we first modified our method and implemented it on a VR head-mounted device with built-in eye tracking. Subsequently, 15 controls naïve to SAP, 15 patients with a neuro-ophthalmological disorder, and 15 glaucoma patients performed three tasks in a counterbalanced manner: (1) a visual tracking task on the VR headset while their EM was recorded, (2) the preceding tracking task but on a conventional screen-based eye tracker, and (3) SAP. We then quantified the spatio-temporal properties (STP) of the EM of each group using a cross-correlogram analysis. Finally, we evaluated the human-computer interaction (HCI) aspects of the participants in the three methods using a user-experience questionnaire. We find that: (1) the VR framework can distinguish the participants according to their oculomotor characteristics; (2) the STP of the VR framework are similar to those from the screen-based eye tracker; and (3) participants from all the groups found the VR-screening test to be the most attractive. Thus, we conclude that the EM-based approach implemented in VR can be a user-friendly and portable companion to complement existing perimetric techniques in ophthalmic clinics.

Indexed as

cross-correlogrameye movementsglaucomaneuro-ophthalmologyperimetryuser experiencevirtual realityvisual field defects

Identifiers

PMID34690682
PMCPMC8526798

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.