Electrochemical sensors for the detection of SARS-CoV-2 virus.

Neeraj Kumar, Nagaraj P Shetti, Somanath Jagannath, Tejraj M Aminabhavi

Open access · bronzeAbstract read
In one paragraph

Article in Chemical engineering journal (Lausanne, Switzerland : 1996), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 79 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
79citing papers in PubMed, 2 pooled it
10.4field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

79 citing papers in PubMed, 2 syntheses or guidelines pooled it, 208 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article

19 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Neeraj KumarDepartment of Inorganic and Physical Chemistry, Indian Institute of Science Bangalore 560012, India.
Nagaraj P ShettiSchool of Advanced Sciences, KLE Technological University, Hubballi 580 031, India.
Somanath JagannathLaboratory of Molecular and Chemical Biology of Neurodegeneration, Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Tejraj M AminabhaviSchool of Advanced Sciences, KLE Technological University, Hubballi 580 031, India.
KLE Technological University · INÉcole Polytechnique Fédérale de Lausanne · CHIndian Institute of Science Bangalore · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coronavirus (COVID-19), a deadly pandemic has spread worldwide and created many global health issues. Though methods of its detection are being continuously developed for the early detection and monitoring of COVID-19, still there is need for more novel methods. The presently used methods include rapid antigen tests, serological surveys, reverse transcription-polymerase chain reaction (RT-PCR), artificial intelligence-based techniques, and assays based on sensors/biosensors. Of all these, RT-PCR test has high sensitivity and specificity though it requires more time for testing and need for skilled technicians. Recently, electrochemical sensors have been developed for rapid monitoring and detection of SARS-CoV-2 from the patient's biological fluid samples. This review covers the recently developed electrochemical sensors that are focused on the detection of viral nucleic acid, immunoglobulin, antigen, and the entire viral particles. In addition, we also compare and assess their detection limits, sensitivities and specificities for the identification and monitoring of COVID-19. Furthermore, this review will address the best practices for the development of electrochemical sensors such as electrode fouling, limit of detection/limit of quantification determination and verification.

Indexed as

BiosensorCOVID-19Electrochemical sensorSARS-CoV-2

Identifiers

PMID34690533
PMCPMC8525496
OpenAlexW3207530931