Evidence map›Paper›PMID 34689581›Full record

ArticleJournal of the American Heart Association2021

Center Variability in Medicare Claims-Based Publicly Reported Transcatheter Aortic Valve Replacement Outcome Measures.

Michael P Thompson, Hechuan Hou, Alexander A Brescia, Francis D Pagani, Devraj Sukul, Jeffrey S McCullough, Donald S Likosky

Abstract read
In one paragraph

Article in Journal of the American Heart Association, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michael P ThompsonDepartment of Cardiac Surgery Michigan Medicine Ann Arbor MI.ORCID 0000-0002-9992-593X
Hechuan HouDepartment of Cardiac Surgery Michigan Medicine Ann Arbor MI.ORCID 0000-0002-0890-0746
Alexander A BresciaDepartment of Cardiac Surgery Michigan Medicine Ann Arbor MI.ORCID 0000-0002-6988-7987
Francis D PaganiDepartment of Cardiac Surgery Michigan Medicine Ann Arbor MI.
Devraj SukulDivision of Cardiovascular Medicine Department of General Internal Medicine Michigan Medicine Ann Arbor MI.ORCID 0000-0003-4709-3390
Jeffrey S McCulloughDepartment of Health Management and Policy School of Public Health University of Michigan Ann Arbor MI.ORCID 0000-0001-6155-980X
Donald S LikoskyDepartment of Cardiac Surgery Michigan Medicine Ann Arbor MI.ORCID 0000-0003-0416-9359

Funding

Evaluating Policies for Improving Surgical Care in the ElderlyR01AG039434 · NIA · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DIMICK, JUSTIN BRIGHAM · 2011 to 2019
$2.9M
NIA NIH HHS R01 AG039434
6 · The paper itself

Abstract

Background Public reporting of transcatheter aortic valve replacement (TAVR) claims-based outcome measures is used to identify high- and low-performing centers. Whether claims-based TAVR outcomes can reliably be used for center-level comparisons is unknown. In this study, we sought to evaluate center variability in claims-based TAVR outcomes used in public reporting. Methods and Results The study sample included 119 554 Medicare beneficiaries undergoing TAVR between January 2014 and October 2018 based on procedure codes in 100% Medicare inpatient claims. Multivariable hierarchical logistic regression was used to estimate center-specific adjusted rates and reliability (R) of 30-day mortality, discharge not to home/self-care, 30-day stroke, and 30-day readmission. Reliability was defined as the ratio of between-hospital variation to the sum of the between- and within-hospital variation. The median (interquartile range [IQR]) center-level adjusted outcome rates were 3.1% (2.9%-3.4%) for 30-day mortality, 41.4% (31.3%-53.4%) for discharge not to home, 2.5% (2.3%-2.7%) for 30-day stroke, and 14.9% (14.4%-15.5%) for 30-day readmission. Median reliability was highest for the discharge not to home measure (R=0.95; IQR, 0.94-0.97), followed by the 30-day stroke (R=0.92; IQR, 0.87-0.94), 30-day mortality (R=0.86; IQR, 0.81-0.91), and 30-day readmission measures (R=0.42; IQR, 0.35-0.51). Across outcomes, there was an inverse relationship between center volume and measure reliability. Conclusions Claims-based TAVR outcome measures for mortality, discharge not to home, and stroke were reliable measures for center-level comparisons, but readmission measures were unreliable. Stakeholders should consider these findings when evaluating claims-based measures to compare center-level TAVR performance.

Indexed as

Aortic Valve StenosisTranscatheter Aortic Valve ReplacementAgedAortic ValveHumansMedicareOutcome Assessment, Health CareReproducibility of ResultsRisk FactorsStrokeTreatment OutcomeUnited Stateshospital profilingoutcomestranscatheter aortic valve replacement

Identifiers

PMID34689581
PMCPMC8751838

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.