ArticleEuropean journal of pediatrics2022
Lung ultrasonography decreases radiation exposure in newborns with respiratory distress: a retrospective cohort study.
Article in European journal of pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04722016 (LUNG ULTRASONOGRAPHY DECREASES RADIATION EXPOSURE), which is not on this map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Lung ultrasonography decreases radiation exposure
Who cites it
9 citing papers in PubMed, 13 citations in OpenAlex.
- Diaphragm ultrasound and lung aeration in small-for-gestational-age versus appropriate-for-gestational-age newborns: a cross-sectional study.Journal of perinatology : official journal of the California Perinatal Association · 2026Article
- Comparison of clinical findings and lung ultrasound scores in newborns with RSV and non-RSV viral lower respiratory tract infections: a prospective observational study.European journal of pediatrics · 2025Observational
- Lung ultrasound for predicting surfactant administration in ventilated and non-ventilated infants with respiratory distress syndrome: a multicenter prospective study.European journal of pediatrics · 2025Observational
- Diagnostic Accuracy of Lung Ultrasound in Neonatal Diseases: A Systematized Review.Journal of clinical medicine · 2024Review
- Our estimates of neonatal radiation exposure fall short of reality.European journal of pediatrics · 2024Article
- Article
- Prediction of respiratory distress severity and bronchopulmonary dysplasia by lung ultrasounds and transthoracic electrical bioimpedance.European journal of pediatrics · 2023Observational
- Application of ultrasonography in neonatal lung disease: An updated review.Frontiers in pediatrics · 2022Review
- Limitations of Bedside Lung Ultrasound in Neonatal Lung Diseases.Frontiers in pediatrics · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Chest X-ray (CXR) is commonly used as a first-line imaging method to determine the cause of respiratory distress in NICUs. The aim of the study was to retrospectively assess the decrease in the number of CXRs performed due to the use of lung ultrasonography on the first day of life for newborns with respiratory distress. Infants who were admitted to the NICU on the first day of life due to respiratory distress were enrolled in this study (ClinicalTrials.gov identifier NCT04722016) and divided into two groups: the study group (n = 104) included patients born between January 2019 and June 2020, and the historical control group (n = 73) included patients born between June 2017 and December 2018. As a first-line technique for lung imaging, only CXR had been used in the historical control group, whereas ultrasound had been preferred in the study group. The radiation dose to the newborns and the number of CXRs performed in the first day of life were compared between the two groups. Significant reductions in the number of CXRs performed and radiation exposure were observed in the study group. The radiation dose decreased from 5.54 to 4.47 µGy per baby when LUS was routinely used. The proportion of patients who underwent CXR decreased from 100 to 71.2%.Conclusion: We observed that using lung ultrasonography as a first-line evaluation method in neonates with respiratory distress decreased both the number of CXRs performed and radiation exposure. What is Known: • Chest X-ray is commonly used as a first line imaging method to diagnose the reason of respiratory distress in NICUs. • Lung ultrasound is a new diagnostic tool for lung imaging. What is New: • With the use of lung ultrasonography, radiation exposure of both newborns and healthcare workers can be reduced. • This retrospective study revealed that most of the babies with respiratory distress were treated without CXR.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.