Evidence map›Paper›PMID 34686761›Full record

ArticleScientific reports2021

Preclinical safety testing and initial experience of a morcellation bag with four sealable ports.

Michael Anapolski, Anja Schellenberger, Ibrahim Alkatout, Dimitrios Panayotopoulos, Alexander Gut, Stefan Soltesz, Sven Schiermeier, Thomas Papathemelis, Günter K Noé

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Michael AnapolskiDepartment of Obstetrics and Gynecology, Community Hospital Dormagen, University of Witten-Herdecke, Dr.-Geldmacher-St. 20, 41540, Dormagen, Germany. michael.anapolski@kkh-ne.de.
Anja SchellenbergerDepartment of Obstetrics and Gynecology, Klinikum Ansbach, Ansbach, Germany.
Ibrahim AlkatoutDepartment of Obstetrics and Gynecology, University Hospitals Schleswig-Holstein, Campus Kiel, Kiel, Germany.
Dimitrios PanayotopoulosDepartment of Obstetrics and Gynecology, Community Hospital Dormagen, Dormagen, Germany.
Alexander GutDepartment of Obstetrics and Gynecology, Community Hospital Grevenbroich, Grevenbroich, Germany.
Stefan SolteszDepartment of Anesthesiology, Community Hospital Dormagen, Dormagen, Germany.
Sven SchiermeierDepartment of Obstetrics and Gynecology, University Witten-Herdecke, Witten, Germany.
Thomas PapathemelisDepartment of Obstetrics and Gynecology, St. Marien Hospital Amberg, Amberg, Germany.
Günter K NoéDepartment of Obstetrics and Gynecology, Community Hospital Dormagen, University of Witten-Herdecke, Dr.-Geldmacher-St. 20, 41540, Dormagen, Germany.
Kreiskrankenhaus Dormagen · DEKlinikum St. Marien Amberg · DEUniversity Hospital Schleswig-Holstein · DEWitten/Herdecke University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electromechanical morcellation-so called power morcellation-is a minimally invasive approach to remove bulky lesions such as uterine fibroids. The spread of benign and malignant tissue due to morcellation is a major concern that might limit the use of laparoscopic interventions. We present an in vitro evaluation of the safety characteristics of a four-port endobag with closable trocar sleeves, and describe physical properties of the bag that may or may not allow passage through the hole. In addition, we report our preliminary experience of this tool when used for laparoscopic supracervical hysterectomies. The behavior of the endobag during the extraction process was analyzed by extracting opened and re-sealed bags filled with 20 ml blue dye solution through a wooden template, with incisions measuring 10 to 24 mm. The endobag was used in 50 subtotal hysterectomies during the morcellation procedure. In the in vitro test, no dye loss was recorded for incisions measuring 11-24 mm. The mean force required to pull the bag through the template was inversely proportional to incision size. No bag rupture occurred during the surgical procedures. The mean time taken to prepare the bag for morcellation was 7.1 min (range, 4-14 min), the mean duration of subtotal hysterectomy was 53.4 min (range, 20-194 min). The mean weight of the removed body of the uterus was 113.8 g (range, 13-896 g), the mean weight of tissue and fluid remaining in the bag after morcellation 7.9 g (range, 0-39 g). In the in vitro setting, the improved endobag signifies greater patient safety during bag extraction, along with less tissue traumatization due to a smaller incision in the abdominal wall. The improved ergonomic features of the bag permit the insertion of three trocars in the lower abdomen and avoid closure of unused access ports. Our preliminary experience has shown that the device can be used under routine conditions. Failure rates will be evaluated in future studies.

Indexed as

FemaleHumansHysterectomyLaparoscopyLeiomyomaMorcellationSurgical InstrumentsUterus

Identifiers

PMID34686761
PMCPMC8536670
OpenAlexW3206173385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.