ArticleMaterials (Basel, Switzerland)2021
Evaluation of Dimensional Changes According to Aging Period and Postcuring Time of 3D-Printed Denture Base Prostheses: An In Vitro Study.
Article in Materials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05958043 (Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations), which is not on this map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Performance of CAD/CAM Milled and 3D-printed Full-arch Implant-supported Provisionals Restorations: A Randomized Controlled Clinical Trial
Who cites it
16 citing papers in PubMed, 26 citations in OpenAlex.
- Mechanical Anisotropy and Fatigue Behavior of 3D-Printed Dentures: A Comparison with CAD/CAM Milled Bases After Thermomechanical Aging.Journal of functional biomaterials · 2026Article
- Does Aging Affect PolyJet™ 3D-Printed Teeth for Endodontics? A Micro-CT Evaluation.Journal of functional biomaterials · 2026Article
- Effect of Printing Orientation on the Dimensional Accuracy of 3D-Printed Denture Base.Journal of functional biomaterials · 2026Article
- Article
- Impact of Printing Orientations on the Trueness and Precision of Additively Fabricated Complete Denture Base Before and After Thermal Aging.Dentistry journal · 2025Article
- Assessment of the trueness of the tissue surface for 3D-printed and injection-molded mandibular complete denture base fabrication.BMC oral health · 2025Article
- Comparison of the Trueness of Complete Dentures Fabricated Using Liquid Crystal Display 3D Printing According to Build Angle and Natural Light Exposure.Journal of functional biomaterials · 2025Article
- Effects of postcuring times on the trueness of 3D -printed dental inlays made with permanent resins.Clinical oral investigations · 2025Article
- Article
- The Applications of 3D-Printing Technology in Prosthodontics: A Review of the Current Literature.Cureus · 2024Review
- Design considerations for digital light processing bioprinters.Applied physics reviews · 2024Review
- The Effect of Build Angle and Artificial Aging on the Accuracy of SLA- and DLP-Printed Occlusal Devices.Polymers · 2024Article
- Article
- Internal and marginal fits of 3D-printed provisional prostheses: comparative effect of different printing parameters.Frontiers in oral health · 2024Article
- Comparative evaluation of the accuracy of 3D-printed denture teeth.The Saudi dental journal · 2023Article
- Effects of Post-Curing Light Intensity on the Mechanical Properties and Three-Dimensional Printing Accuracy of Interim Dental Material.Materials (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
During the three-dimensional (3D) printing process of a dental prosthesis, using photopolymer resin, partially polymerized resin is further cured through the postcuring process that proceeds after the printing, which improves the stability of the printed product. The mechanical properties of the end product are known to be poor if the postcuring time is insufficient. Therefore, this study evaluated the effect of the postcuring time of the 3D-printed denture base on its dimensional stability, according to the aging period. The 3D prints were processed after designing maxillary and mandibular denture bases, and after the following postcuring times were applied: no postcuring, and 5, 15, 30, and 60 min. The dimensional stability change of the denture base was evaluated and analyzed for 28 days after the postcuring process. The trueness analysis indicated that the mandibular denture base had lower output accuracy than the maxillary denture base, and the dimensional stability change increased as postcuring progressed. In the no postcuring group for the mandible, the error value was 201.1 ± 5.5 µm (mean ± standard deviation) after 28 days, whereas it was 125.7 ± 13.0 µm in the 60 min postcuring group. For both the maxilla and the mandible, shorter postcuring times induced larger dimensional stability changes during the aging process. These findings indicate that in order to manufacture a denture base with dimensional stability, a sufficient postcuring process is required during the processing stage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.