ArticleMicromachines2021
A High-Resolution Electric Current Sensor Employing a Piezoelectric Drum Transducer.
Article in Micromachines, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
Abstract
A high-resolution sensor using a piezoelectric drum transducer is proposed for power frequency current sensing (50 Hz or 60 Hz). The utilization of the magnetic circuit helps to enhance the response to the electric currents in the power cords. The high sensitivity of the sensor originates from the superposition of the Ampere forces and the amplified piezoelectric effect of the drum transducer. The feasibility of the sensor was verified by experiments. The device exhibits a broad 3 dB bandwidth of 67.4 Hz without an additional magnetic field bias. The average sensitivity is 31.34 mV/A with a high linearity of 0.49%, and the resolution of the sensor attains 0.02 A. The resolution is much higher than that of the previous piezoelectric heterostructure for two-wire power-cords. Error analysis shows that the uncertainty reaches 0.01865 mV at the current of 2.5 A. Meanwhile, the device can generate a load power of 447.9 nW with an optimal load resistance of 55 KΩ at 10A (
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.