Evidence map›Paper›PMID 34682351›Full record

ReviewInternational journal of environmental research and public health2021

Core Temperature Measurement-Principles of Correct Measurement, Problems, and Complications.

Hubert Hymczak, Aleksandra Gołąb, Konrad Mendrala, Dariusz Plicner, Tomasz Darocha, Paweł Podsiadło, Damian Hudziak, Radosław Gocoł, Sylweriusz Kosiński

2 registry-linked trialsAbstract readReview
In one paragraph

Review in International journal of environmental research and public health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 71 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
71citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07507396 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Non-invasive Temperature Monitoring in Pediatric Intensive Care Patients Requiring Targeted Temperature Management: Evaluation of Temple Touch Pro

TypeinterventionalSponsorMedical College of WisconsinRan2026 to 2027Enrolled20ConditionsTemperature MonitoringArmsTemple Touch Pro
NCT07617649 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Laboratory Based Identification of Heat Stress Biomarkers and Effective Cooling Interventions

TypeinterventionalSponsorStanford UniversityRan2026 to 2028Enrolled30ConditionsHyperthermiaArmsHand cooling table, Cooling bandana
3 · Its place in the literature

Who cites it

71 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Review
  6. Functional thermodynamics govern the ligand binding to human cytosolic transport proteins.Protein science : a publication of the Protein Society · 2026
    Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Emergency care for avalanche buried patients - a narrative review.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026
    Review
  15. Review
  16. Article
  17. Article
  18. Review
  19. Article
  20. Review

11 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hubert HymczakDepartment of Anesthesiology and Intensive Care, John Paul II Hospital, 31-202 Krakow, Poland.
Aleksandra GołąbFaculty of Medicine and Dentistry, Pomeranian Medical University, 70-204 Szczecin, Poland.ORCID 0000-0003-4773-7512
Konrad MendralaDepartment of Anaesthesiology and Intensive Care, Medical University of Silesia, 40-055 Katowice, Poland.ORCID 0000-0002-9019-0420
Dariusz PlicnerFaculty of Medicine and Health Sciences, Andrzej Frycz Modrzewski Krakow University, 30-705 Krakow, Poland.ORCID 0000-0002-3687-512X
Tomasz DarochaDepartment of Anaesthesiology and Intensive Care, Medical University of Silesia, 40-055 Katowice, Poland.
Paweł PodsiadłoInstitute of Medical Sciences, Jan Kochanowski University, 25-369 Kielce, Poland.ORCID 0000-0002-1069-2659
Damian HudziakDepartment of Cardiac Surgery, Upper-Silesian Heart Center, 40-055 Katowice, Poland.ORCID 0000-0003-3715-0697
Radosław GocołDepartment of Cardiac Surgery, Upper-Silesian Heart Center, 40-055 Katowice, Poland.
Sylweriusz KosińskiFaculty of Health Sciences, Jagiellonian University Medical College, 31-008 Krakow, Poland.ORCID 0000-0002-6680-4525

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Core temperature reflects the temperature of the internal organs. Proper temperature measurement is essential to diagnose and treat temperature impairment in patients. However, an accurate approach has yet to be established. Depending on the method used, the obtained values may vary and differ from the actual core temperature. There is an ongoing debate regarding the most appropriate anatomical site for core temperature measurement. Although the measurement of body core temperature through a pulmonary artery catheter is commonly cited as the gold standard, the esophageal temperature measurement appears to be a reasonable and functional alternative in the clinical setting. This article provides an integrative review of invasive and noninvasive body temperature measurements and their relations to core temperature.

Indexed as

Body TemperatureResearch DesignHumansTemperaturecore temperaturemeasurementthermoregulation

Identifiers

PMID34682351
PMCPMC8535559

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.