ReviewInternational journal of environmental research and public health2021
Core Temperature Measurement-Principles of Correct Measurement, Problems, and Complications.
Review in International journal of environmental research and public health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 71 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Non-invasive Temperature Monitoring in Pediatric Intensive Care Patients Requiring Targeted Temperature Management: Evaluation of Temple Touch Pro
Laboratory Based Identification of Heat Stress Biomarkers and Effective Cooling Interventions
Who cites it
71 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Hyperthermia during open water swimming: risks, monitoring and mitigation strategies.European journal of applied physiology · 2025Pooled it
- The Effect of Brief Warming during Induction of General Anesthesia and Warmed Intravenous Fluid on Intraoperative Hypothermia in Patients Undergoing Urologic Surgery.Medicina (Kaunas, Lithuania) · 2024Trial
- Factors influencing acute tympanic temperature changes during cold water exposure.International journal of circumpolar health · 2026Article
- Thermographic assessment of surface temperature distribution and agreement between a thermographic camera, infrared thermometer, and rectal temperature in exercising horses under tropical climate conditions.Veterinary world · 2026Article
- Advances and Challenges in Wearable Sensors for Health Monitoring.ACS applied materials & interfaces · 2026Review
- Functional thermodynamics govern the ligand binding to human cytosolic transport proteins.Protein science : a publication of the Protein Society · 2026Article
- Does low-temperature dialysis still represent an advantage?: a narrative review from the last decade.International urology and nephrology · 2026Review
- Continuous wireless temperature monitoring using TempTraq® in children.Pediatric research · 2026Article
- Data-driven estimation of core body temperature during physical activity under heat exposure: A systematic review and standardized evaluation.Building and environment · 2026Review
- Article
- Personal Protective Equipment Immediately Alters the Core-Skin Temperature Gradient in Recruit Firefighters.Life (Basel, Switzerland) · 2026Article
- Approach to Low Body Temperature or Mild Hypothermia in the Geriatric Population: A Narrative Review.Journal of clinical medicine research · 2026Review
- Performance of a transesophageal echocardiography probe at temperature monitoring during simulated hypothermia and rewarming.Clinical and experimental emergency medicine · 2026Article
- Emergency care for avalanche buried patients - a narrative review.Scandinavian journal of trauma, resuscitation and emergency medicine · 2026Review
- A Comprehensive Review of Non-Invasive Core Body Temperature Measurement Techniques.Sensors (Basel, Switzerland) · 2026Review
- Article
- Acute Finnish sauna heat exposure induces stronger immune cell than cytokine responses.Temperature (Austin, Tex.) · 2026Article
- Core temperature measurement methods and their accuracy in pediatric intensive care units: a narrative review.Frontiers in pediatrics · 2026Review
- Recurrent hypothermia associated with atypical antipsychotics: a diagnostic challenge in a medically complex patient.Archive of clinical cases · 2026Article
- Schiff base metal complexes as emerging therapeutics against antimicrobial-resistant skin pathogens.ADMET & DMPK · 2026Review
11 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Core temperature reflects the temperature of the internal organs. Proper temperature measurement is essential to diagnose and treat temperature impairment in patients. However, an accurate approach has yet to be established. Depending on the method used, the obtained values may vary and differ from the actual core temperature. There is an ongoing debate regarding the most appropriate anatomical site for core temperature measurement. Although the measurement of body core temperature through a pulmonary artery catheter is commonly cited as the gold standard, the esophageal temperature measurement appears to be a reasonable and functional alternative in the clinical setting. This article provides an integrative review of invasive and noninvasive body temperature measurements and their relations to core temperature.