ArticleBiomolecules2021
Automated Fiber Diameter and Porosity Measurements of Plasma Clots in Scanning Electron Microscopy Images.
Article in Biomolecules, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Indium Tin Oxide (ITO) Substrates Enable Coating-Free SEM Imaging and Simplified Preparation of Purified Fibrinogen Clots.bioRxiv : the preprint server for biology · 2026Article
- Effect of Perfluorooctanesulfonic Acid on Fibrin Clot Properties and Thrombin Generation: Linking Environmental Pollution with Cardiovascular Diseases.Journal of cardiovascular development and disease · 2026Article
- High-throughput Image-based Matrix Analysis Platform Software: development of an algorithm for standardized characterization of high-resolution fibrin clot images.Research and practice in thrombosis and haemostasis · 2026Article
- Extracellular vesicles in pregnancy-related disorders: from mechanisms to clinical implications.Science China. Life sciences · 2026Review
- Fibrin as a Versatile Fibrous Biopolymer.Sub-cellular biochemistry · 2026Review
- Plasma from patients with pulmonary embolism show aggregates that reduce after anticoagulation.Communications medicine · 2023Article
- A guide to molecular and functional investigations of platelets to bridge basic and clinical sciences.Nature cardiovascular research · 2022Article
- Comparison of Fibrin Characteristics and Cellular Contents of Injectable Platelet-rich Fibrin Enriched Bone Block ("Sticky Bone") Prepared Using Novel and Traditional Protocols - AnContemporary clinical dentistryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Scanning Electron Microscopy (SEM) is a powerful, high-resolution imaging technique widely used to analyze the structure of fibrin networks. Currently, structural features, such as fiber diameter, length, density, and porosity, are mostly analyzed manually, which is tedious and may introduce user bias. A reliable, automated structural image analysis method would mitigate these drawbacks. We evaluated the performance of DiameterJ (an ImageJ plug-in) for analyzing fibrin fiber diameter by comparing automated DiameterJ outputs with manual diameter measurements in four SEM data sets with different imaging parameters. We also investigated correlations between biophysical fibrin clot properties and diameter, and between clot permeability and DiameterJ-determined clot porosity. Several of the 24 DiameterJ algorithms returned diameter values that highly correlated with and closely matched the values of the manual measurements. However, optimal performance was dependent on the pixel size of the images-best results were obtained for images with a pixel size of 8-10 nm (13-16 pixels/fiber). Larger or smaller pixels resulted in an over- or underestimation of diameter values, respectively. The correlation between clot permeability and DiameterJ-determined clot porosity was modest, likely because it is difficult to establish the correct image depth of field in this analysis. In conclusion, several DiameterJ algorithms (M6, M5, T3) perform well for diameter determination from SEM images, given the appropriate imaging conditions (13-16 pixels/fiber). Determining fibrin clot porosity via DiameterJ is challenging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.