ArticleDiagnostics (Basel, Switzerland)2021

Visual Evaluation of Image Quality of a Low Dose 2D/3D Slot Scanner Imaging System Compared to Two Conventional Digital Radiography X-ray Imaging Systems.

Ahmed Jibril Abdi, Bo Mussmann, Alistair Mackenzie, Oke Gerke, Gitte Maria Jørgensen, Thor Eriksen Bechsgaard, Janni Jensen, Lone Brunshøj Olsen, Poul Erik Andersen

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Ahmed Jibril AbdiDepartment of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark.ORCID 0000-0001-6796-6692
Bo MussmannDepartment of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark.ORCID 0000-0003-2119-5129
Alistair MackenzieNational Coordinating Centre for the Physics of Mammography, Royal Surrey NHS Foundation Trust, Guildford GU2 7XX, UK.ORCID 0000-0003-4545-8018
Oke GerkeDepartment of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark.ORCID 0000-0001-6335-3303
Gitte Maria JørgensenDepartment of Radiology, Odense University Hospital, 5000 Odense, Denmark.
Thor Eriksen BechsgaardDepartment of Radiology, Odense University Hospital, 5000 Odense, Denmark.
Janni JensenDepartment of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark.ORCID 0000-0001-7036-6129
Lone Brunshøj OlsenDepartment of Radiology, Odense University Hospital, 5000 Odense, Denmark.
Poul Erik AndersenDepartment of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark.
University of Southern Denmark · DKOdense University Hospital · DKRoyal Surrey NHS Foundation Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to assess the image quality of the low dose 2D/3D slot scanner (LDSS) imaging system compared to conventional digital radiography (DR) imaging systems. Visual image quality was assessed using the visual grading analysis (VGA) method. This method is a subjective approach that uses a human observer to evaluate and optimise radiographic images for different imaging technologies. METHODS AND MATERIALS: ten posterior-anterior (PA) and ten lateral (LAT) images of a chest anthropomorphic phantoms and a knee phantom were acquired by an LDSS imaging system and two conventional DR imaging systems. The images were shown in random order to three (chest) radiologists and three experienced (knee) radiographers, who scored the images against a number of criteria. Inter- and intraobserver agreement was assessed using Fleiss' kappa and weighted kappa.

resultsthe statistical comparison of the agreement between the observers showed good interobserver agreement, with Fleiss' kappa coefficients of 0.27-0.63 and 0.23-0.45 for the chest and knee protocols, respectively. Comparison of intraobserver agreement also showed good agreement with weighted kappa coefficients of 0.27-0.63 and 0.23-0.45 for the chest and knee protocols, respectively. The LDSS imaging system achieved significantly higher VGA image quality compared to the DR imaging systems in the AP and LAT chest protocols (

conclusionsthis work has shown that the LDSS imaging system has the potential to acquire chest and knee images at diagnostic quality and at a lower effective dose than DR systems.

Indexed as

chest examinationDR imaging systemsimage quality assessmentknee examinationslot scanner imaging systemvisual grading analysis