Evidence map›Paper›PMID 34679588›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Improving Blood Flow Visualization of Recirculation Regions at Carotid Bulb in 4D Flow MRI Using Semi-Automatic Segmentation with ITK-SNAP.

Minh Tri Ngo, Ui Yun Lee, Hojin Ha, Jinmu Jung, Dong Hwan Lee, Hyo Sung Kwak

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Minh Tri NgoDepartment of Radiology of Hue Central Hospital, Hue, Thua Thien Hue 530000, Vietnam.ORCID 0000-0002-0623-4778
Ui Yun LeeDivision of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea.ORCID 0000-0002-1366-6878
Hojin HaDepartment of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea.
Jinmu JungDivision of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea.
Dong Hwan LeeDivision of Mechanical Design Engineering, College of Engineering, Jeonbuk National University, Jeon-ju 54896, Korea.
Hyo Sung KwakDepartment of Radiology and Research Institute of Clinical Medicine of Jeonbuk National University, Biomedical Research Institute of Jeonbuk National University Hospital, Jeon-ju 54907, Korea.ORCID 0000-0002-7228-8117

Funding

National Research Foundation of Korea NRF-2019R1I1A3A01059720National Research Foundation of Korea NRF-2019R1I1A3A01060695National Research Foundation of Korea NRF-2020R1A2C1008089National Research Foundation of Korea NRF-2020R1A4A2002817
6 · The paper itself

Abstract

Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.

Indexed as

carotid bulbcomputational fluid dynamicsfour-dimensional flow magnetic resonance imagingITK-SNAPrecirculation regions

Identifiers

PMID34679588
PMCPMC8534781

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.