Evaluation of the New Beckmann Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency.

Maite Serrando Querol, Javier Nieto-Moragas, Anna Marull Arnall, Meritxell Deulofeu Figueras, Orlando Jiménez-Romero

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maite Serrando QuerolHematology Laboratory, Hospital Universitari de Girona Doctor Josep Trueta, 17190 Girona, Catalonia, Spain.ORCID 0000-0002-9983-9767
Javier Nieto-MoragasHematology Laboratory, Hospital Universitari de Girona Doctor Josep Trueta, 17190 Girona, Catalonia, Spain.ORCID 0000-0003-0719-2589
Anna Marull ArnallHematology Laboratory, Hospital Universitari de Girona Doctor Josep Trueta, 17190 Girona, Catalonia, Spain.
Meritxell Deulofeu FiguerasHematology Laboratory, Hospital Universitari de Girona Doctor Josep Trueta, 17190 Girona, Catalonia, Spain.
Orlando Jiménez-RomeroHematology Laboratory, Hospital Universitari de Girona Doctor Josep Trueta, 17190 Girona, Catalonia, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Efficiency and accuracy in automated hematology analyzers are very important for clinical laboratories. The purpose was to evaluate the flags and results reported by the newest Beckman Coulter analyzer DxH 900 compared to the Sysmex XN20 system. Samples were analyzed on the XN20 (Sysmex, Kobe, Japan) and on the Beckman Coulter DxH 900 (Beckman Coulter, Miami, Florida, USA). Slide reviews were performed microscopically. Morphologic criteria were used to identify abnormal cells as recommended by International Consensus Group for Hematology (ICSH): blasts, immature granulocytes (IG%), abnormal lymphocytes (ALs) and plasma cells. Results: there was a strong correlation between the analyzers in almost all clinical parameters tested. Both DxH 900 and XN20 showed an excellent degree of association for the leukocyte differential compared to the reference method (manual microscopy). When it comes to IG%, XN20 showed a positive bias for higher results. Related to platelets, there are no differences between the two methods for PLT count. For mean platelet volume (MPV), DxH 900 provided 100% results of the samples analyzed while XN20 while in the XN20 analyzer, 16% of the results were missing. From our results we came to the conclusion that both analyzers, DxH 900 and XN20 were clinically accurate and efficient. Abnormal Lymphocyte detection highlighted the differences between the two technologies as only minimal agreement was obtained. DxH 900 demonstrated higher sensitivity in detecting IG with good correlation with microscopic review. The DxH 900 for platelet clumps identification provides an excellent flag (PLT Clumps) with the highest sensitivity observed in our evaluation.

Indexed as

Beckman Coulter DxH 900cell blood count (CBC)leukocyte differentialSysmex XN20

Identifiers

PMID34679454
PMCPMC8535162

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.