Evidence map›Paper›PMID 34677361›Full record

ReviewBiosensors2021

A Review of Capillary Pressure Control Valves in Microfluidics.

Shaoxi Wang, Xiafeng Zhang, Cong Ma, Sheng Yan, David Inglis, Shilun Feng

Open access · goldAbstract readReview
In one paragraph

Review in Biosensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Review
  3. Microfluidic valves for wearable sweat analysis: a review.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026
    Review
  4. Responsive Open Microfluidic Logic for Mechanical Computing.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. A Wearable In-Pad Diagnostic for the Detection of Disease Biomarkers in Menstruation Blood.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Interfacial tension driven open droplet microfluidics.Advanced materials interfaces · 2023
    Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 3 countries.

Shaoxi WangSchool of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, China.ORCID 0000-0002-0230-2059
Xiafeng ZhangSchool of Microelectronics, Northwestern Polytechnical University, Xi'an 710072, China.
Cong MaState Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
Sheng YanInstitute for Advanced Study, Shenzhen University, Shenzhen 518060, China.ORCID 0000-0002-3463-0786
David InglisSchool of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW 2109, Australia.ORCID 0000-0001-8239-5568
Shilun FengState Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.
Northwestern Polytechnical University · CNChinese Academy of Sciences · CNMacquarie University · AUNanyang Technological University · SGShenzhen University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microfluidics offer microenvironments for reagent delivery, handling, mixing, reaction, and detection, but often demand the affiliated equipment for liquid control for these functions. As a helpful tool, the capillary pressure control valve (CPCV) has become popular to avoid using affiliated equipment. Liquid can be handled in a controlled manner by using the bubble pressure effects. In this paper, we analyze and categorize the CPCVs via three determining parameters: surface tension, contact angle, and microchannel shape. Finally, a few application scenarios and impacts of CPCV are listed, which includes how CPVC simplify automation of microfluidic networks, work with other driving modes; make extensive use of microfluidics by open channel, and sampling and delivery with controlled manners. The authors hope this review will help the development and use of the CPCV in microfluidic fields in both research and industry.

Indexed as

MicrofluidicsAutomationCapillariesEquipment Designcapillary pressure control valve (CPCV)microfluidicspassive valve

Identifiers

PMID34677361
PMCPMC8533935
OpenAlexW3206689429

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.