Evidence map›Paper›PMID 34677102›Full record

ArticleActa radiologica (Stockholm, Sweden : 1987)2022

In vitro CT visualization of the biopsy location by filling the core biopsy needle with contrast media.

Per Thunswärd, David Eksell, Håkan Ahlström, Anders Magnusson

Abstract read
In one paragraph

Article in Acta radiologica (Stockholm, Sweden : 1987), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Per ThunswärdDepartment of Surgical Sciences - Radiology, 8097Uppsala University, Uppsala, Sweden.ORCID 0000-0002-1059-2543
David EksellDepartment of Surgical Sciences - Radiology, 8097Uppsala University, Uppsala, Sweden.
Håkan AhlströmDepartment of Surgical Sciences - Radiology, 8097Uppsala University, Uppsala, Sweden.
Anders MagnussonDepartment of Surgical Sciences - Radiology, 8097Uppsala University, Uppsala, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhen performing computed tomography (CT)-guided biopsy procedures with non-disposable, automatic biopsy instruments, the actual course of the biopsy needle is not registered. PURPOSE: To evaluate the ability to visualize the sampling location after CT-guided biopsy in vitro using a novel method, where the space between the inner needle and the outer cannula in a core biopsy needle is filled with contrast media; and to compare the grade of visibility for two different concentrations of contrast media. MATERIAL AND

methodsCore needle biopsies were performed in a tissue phantom using biopsy needles primed with two different iodine contrast media concentrations (140 mg I/mL and 400 mg I/mL). Commercially available needle-filling contraptions with sealing membranes were used to fill the needles. Each biopsy was imaged with CT, and the visibility was evaluated twice by three senior radiologists in a randomized order.

resultsThe presence of traces was confirmed after biopsy, almost without exception for both concentrations. The visibility was sufficient to determine the biopsy location in all observations with the 400 mg I/mL filling, and in 7/10 observations with the 140 mg I/mL filling. The grade of visibility of the trace and the proportion of the biopsy needle course outlined were higher with the 400 mg I/mL filling.

conclusionWith CT-guided biopsy in vitro, the sampling location can be visualized using a novel method of priming the biopsy needle with iodine contrast media, specifically highly concentrated contrast media.

Indexed as

Contrast MediaIodineBiopsy, Large-Core NeedleHumansImage-Guided BiopsyNeedlesRadiography, InterventionalTomography, X-Ray ComputedContrast MediaIodineBiopsyContrast Agents-OtherCTExperimental Investigations

Identifiers

PMID34677102
PMCPMC9490437

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.