Evidence map›Paper›PMID 34675166›Full record

ArticleThe American journal of case reports2021

A 37-Year-Old Woman with Hypertrophic Cardiomyopathy with a Dual-Chamber Implantable Cardioverter-Defibrillator Requiring Percutaneous Transvenous Lead Extraction and Multidisciplinary Management.

Rahul Dhawan, Faris Khan, Saurabhi Samant, Majid Asawaeer, HelenMari Merritt Genore, Christopher C Erickson

Open access · hybridAbstract readCase Reports
In one paragraph

Article in The American journal of case reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Rahul DhawanDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
Faris KhanDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
Saurabhi SamantDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
Majid AsawaeerDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
HelenMari Merritt GenoreDepartment of Surgery, Division of Cardiothoracic Surgery, University of Nebraska Medical Center, Omaha, NE, USA.ORCID 0000-0002-2095-5643
Christopher C EricksonDepartment of Internal Medicine, Division of Cardiovascular Medicine, University of Nebraska Medical Center, Omaha, NE, USA.
University of Nebraska Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND Percutaneous transvenous lead extraction (TLE) of cardiac implantable electronic devices can be performed with a high success rate. However, TLE has its limitations and challenges. Recognizing the challenges at an early stage during the procedure is vital for appropriate patient management. We present a challenging case of implantable cardioverter-defibrillator (ICD) lead extraction in which we aborted TLE in favor of elective surgical extraction (SE). This potentially prevented a major catastrophic complication of vascular tear, which would have required an emergent thoracotomy. CASE REPORT A 37-year-old woman with history of hypertrophic cardiomyopathy had a primary prevention dual-chamber ICD implant in 2001 and underwent right ventricular ICD lead revision in 2009 due to lead fracture. In 2019, she was again found to have right ventricular ICD lead malfunction. TLE was attempted, but no meaningful progression could be made despite using multiple extraction tools. Therefore, TLE was aborted in favor of SE. During elective SE, significant adhesions were noted, and the innominate vein was completely avulsed during removal of the leads, requiring venous reconstruction by the vascular surgery team. After SE and vascular reconstruction, an epicardial ICD system was placed, and the patient had an uneventful postoperative recovery. CONCLUSIONS This case report highlights the limitations of TLE and the importance of recognizing them in a timely manner. In all challenging cases, conversion to elective SE should be considered to avoid potential injuries warranting emergent surgical repair.

Indexed as

Cardiomyopathy, HypertrophicDefibrillators, ImplantableAdultDevice RemovalFemaleHumansTissue AdhesionsTreatment Outcome

Identifiers

PMID34675166
PMCPMC8546269
OpenAlexW3204516536

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.