Evidence map›Paper›PMID 34674136›Full record

ArticleInternational journal of computer assisted radiology and surgery2022

Aorta-aware GAN for non-contrast to artery contrasted CT translation and its application to abdominal aortic aneurysm detection.

Tao Hu, Masahiro Oda, Yuichiro Hayashi, Zhongyang Lu, Kanako Kunishima Kumamaru, Toshiaki Akashi, Shigeki Aoki, Kensaku Mori

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Tao HuGraduate School of Informatics, Nagoya University, Chikusa-ku, Nagoya, Aichi, Japan.ORCID http://orcid.org/0000-0002-7667-1666
Masahiro OdaGraduate School of Informatics, Nagoya University, Chikusa-ku, Nagoya, Aichi, Japan.
Yuichiro HayashiGraduate School of Informatics, Nagoya University, Chikusa-ku, Nagoya, Aichi, Japan.
Zhongyang LuGraduate School of Informatics, Nagoya University, Chikusa-ku, Nagoya, Aichi, Japan.
Kanako Kunishima KumamaruDepartment of Radiology, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Toshiaki AkashiDepartment of Radiology, Juntendo University, Bunkyo-ku, Tokyo, Japan.
Shigeki AokiDepartment of Radiology, Juntendo University, Bunkyo-ku, Tokyo, Japan.ORCID http://orcid.org/0000-0002-8491-0698
Kensaku MoriGraduate School of Informatics, Nagoya University, Chikusa-ku, Nagoya, Aichi, Japan. kensaku@is.nagoya-u.ac.jp.ORCID https://orcid.org/0000-0002-0100-4797
Nagoya University · JPJuntendo University · JPNational Institute of Informatics · JP

Funding

Japan Agency for Medical Research and Development JP19lk1010036Japan Agency for Medical Research and Development JP20lk1010036Japan Society for the Promotion of Science 17H00867Japan Society for the Promotion of Science 17K20099Japan Society for the Promotion of Science 26108006
6 · The paper itself

Abstract

purposeArtery contrasted computed tomography (CT) enables accurate observations of the arteries and surrounding structures, thus being widely used for the diagnosis of diseases such as aneurysm. To avoid the complications caused by contrast agent, this paper proposes an aorta-aware deep learning method to synthesize artery contrasted CT volume form non-contrast CT volume.

methodsBy introducing auxiliary multi-resolution segmentation tasks in the generator, we force the proposed network to focus on the regions of aorta and the other vascular structures. Then, the segmentation results produced by the auxiliary tasks were used to extract aorta. The detection of abnormal CT images containing aneurysm was implemented by estimating the maximum axial radius of aorta.

resultsIn comparison with the baseline models, the proposed network with auxiliary tasks achieved better performances with higher peak signal-noise ratio value. In aorta regions which are supposed to be the main region of interest in many clinic scenarios, the average improvement can be up to 0.33dB. Using the synthesized artery contrasted CT, the F score of aneurysm detection achieved 0.58 at slice level and 0.85 at case level.

conclusionThis study tries to address the problem of non-contrast to artery contrasted CT modality translation by employing a deep learning model with aorta awareness. The auxiliary tasks help the proposed model focus on aorta regions and synthesize results with clearer boundaries. Additionally, the synthesized artery contrasted CT shows potential in identifying slices with abdominal aortic aneurysm, and may provide an option for patients with contrast agent allergy.

Indexed as

Aortic Aneurysm, AbdominalAortaHumansTomography, X-Ray ComputedAuxiliary taskContrast CT analysisDeep learningModality translation

Identifiers

PMID34674136
OpenAlexW3206402530

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.