ArticleMedical & biological engineering & computing2021
Biomechanical investigation of topping-off technique using an interspinous process device following lumbar interbody fusion under vibration loading.
Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Topping-off technique has been proposed to prevent adjacent-segment degeneration/disease following spine fusion surgery. Nevertheless, few studies have investigated biomechanics of the fusion surgery with topping-off device under whole-body vibration (WBV). This biomechanical study aimed to investigate the vibration characteristics of human lumbar spine after topping-off surgery, and also to evaluate the effect of bony fusion on spine biomechanics. Based on a healthy finite-element model of lumbosacral spine (L1-sacrum), the models of topping-off surgery before and after bony fusion were developed. The simulated surgical procedures consisted of interbody fusion with rigid stabilizer at L4-L5 segment (rigid fusion) and dynamic stabilizer at degenerated L3-L4 segment. An interspinous implant, Device for Intervertebral Assisted Motion (DIAM, Medtronic Inc., Minnesota, USA), was used as the dynamic stabilizer. The stress responses of spine segments and implants under a vertical cyclic load were calculated and analyzed. The results showed that compared with rigid fusion alone, the topping-off technique significantly decreased disc stress at transition segment (L3-L4) as expected, and resulted in a slight increase in disc stress at its supra-adjacent segment (L2-L3). It indicated that the topping-off stabilization using DIAM might provide a good tradeoff between protection of transition segment and deterioration of its supra-adjacent segment during WBV. Also, it was found that bony fusion decreased stress in L4 inferior endplate and rigid stabilizer but had nearly no effect on stress in DIAM and L3-L4 disc, which was helpful to determine the biomechanical differences before and after bony fusion.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.