Finite Element Analysis of a Novel Anterior Locking Plate for Thoracolumbar Burst Fracture.

Pengcheng Ren, Xiaodong Cheng, Chongyao Lu, Haotian Wu, Shuangquan Yao, Sidong Yang, Zhaohui Song

Open access · hybridAbstract read
In one paragraph

Article in BioMed research international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 2 countries.

Pengcheng RenDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.ORCID https://orcid.org/0000-0002-9667-5568
Xiaodong ChengKey Laboratory of Biomechanics of Hebei Province, Shijiazhuang, Hebei, China.
Chongyao LuDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.
Haotian WuDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.
Shuangquan YaoDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.
Sidong YangDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.ORCID https://orcid.org/0000-0003-2342-4714
Zhaohui SongDepartment of Orthopedic Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Qiaoxi District, Shijiazhuang 050051, China.ORCID https://orcid.org/0000-0003-3000-8014
Hebei Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe finite element analysis method was used to explore the biomechanical stability of a novel locking plate for thoracolumbar burst fracture fusion fixation.

methodsThe thoracolumbar CT imaging data from a normal volunteer was imported into finite software to build a normal model and three different simulated surgical models (the traditional double-segment fixation model A, the novel double-segment fixation model B, and the novel single-segment fixation model C). An axial pressure (500 N) and a torque (10 Nm) were exerted on the end plate of T12 to simulate activity of the spine. We recorded the range of motion (ROM) and the maximum stress value of the simulated cages and internal fixations.

resultsModel A has a larger ROM in all directions than model B (flexion 5.63%, extension 38.21%, left rotation 46.51%, right rotation 39.76%, left bending 9.45%, and right bending 11.45%). Model C also has a larger ROM in all directions than model B (flexion 555.63%, extension 51.42%, left rotation 56.98%, right rotation 55.42%, left bending 65.67%, and right bending 59.47%). The maximum stress of the cage in model A is smaller than that in model B except for the extension direction (flexion 96.81%, left rotation 175.96%, right rotation 265.73%, left bending 73.73%, and right bending 171.28%). The maximum stress value of the internal fixation in model A is greater than that in model B when models move in flexion (20.23%), extension (117.43%), and left rotation (21.34%).

conclusionThe novel locking plate has a smaller structure and better performance in biomechanical stability, which may be more compatible with minimally invasive spinal tubular technology.

Indexed as

Biomechanical PhenomenaBone PlatesComputer SimulationFinite Element AnalysisFracture Fixation, InternalHumansLumbar VertebraeRange of Motion, ArticularSpinal Fusion

Identifiers

PMID34671672
PMCPMC8523228
OpenAlexW3205931932

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.