Evidence map›Paper›PMID 34670749›Full record

ArticleThe British journal of ophthalmology2023

Generalisability and performance of an OCT-based deep learning classifier for community-based and hospital-based detection of gonioscopic angle closure.

Jasmeen Randhawa, Michael Chiang, Natalia Porporato, Anmol A Pardeshi, Justin Dredge, Galo Apolo Aroca, Tin A Tun, Joanne HuiMin Quah, Marcus Tan, Risa Higashita and 3 more

Open access · greenAbstract read
In one paragraph

Article in The British journal of ophthalmology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 1 pooled it
3.6field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 1 synthesis or guideline pooled it, 26 citations in OpenAlex.

  1. Pooled it
  2. Artificial Intelligence for Optical Coherence Tomography in Glaucoma.Translational vision science & technology · 2025
    Review
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Review
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 6 institutions in 3 countries.

Jasmeen RandhawaKeck School of Medicine of the University of Southern California, Los Angeles, California, USA.
Michael ChiangRoski Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.
Natalia PorporatoSingapore National Eye Centre, Singapore Eye Research Institute, Singapore.
Anmol A PardeshiRoski Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.
Justin DredgeRoski Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.
Galo Apolo ArocaRoski Eye Institute, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA.ORCID 0000-0001-5751-6102
Tin A TunSingapore National Eye Centre, Singapore Eye Research Institute, Singapore.
Joanne HuiMin QuahOutram Polyclinic, SingHealth Polyclinics, Singapore.
Marcus TanOphthalmology, National University of Singapore, Singapore.
Risa HigashitaTomey Corporation, Nagoya, Japan.
Tin AungSingapore National Eye Centre, Singapore Eye Research Institute, Singapore.
Rohit VarmaSouthern California Eye Institute, CHA Hollywood Presbyterian Medical Center, Los Angeles, California, USA.
Benjamin Y XuKeck School of Medicine of the University of Southern California, Los Angeles, California, USA Benjamin.Xu@med.usc.edu.ORCID 0000-0003-1573-988X
University of Southern California · USNational University of Singapore · SGSingapore National Eye Center · SGPenn Presbyterian Medical Center · USSingHealth Polyclinics · SGTomey (Japan) · JP

Funding

Chinese American Eye StudyU10EY017337 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI VARMA, ROHIT · 2009 to 2013
$10.2M
Development and Validation of Quantitative Anterior Segment OCT-based Methods to Evaluate Patients with Primary Angle Closure DiseaseK23EY029763 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI XU, BENJAMIN Y. · 2019 to 2023
$1.1M
NEI NIH HHS K23 EY029763NEI NIH HHS U10 EY017337
6 · The paper itself

Abstract

purposeTo assess the generalisability and performance of a deep learning classifier for automated detection of gonioscopic angle closure in anterior segment optical coherence tomography (AS-OCT) images.

methodsA convolutional neural network (CNN) model developed using data from the Chinese American Eye Study (CHES) was used to detect gonioscopic angle closure in AS-OCT images with reference gonioscopy grades provided by trained ophthalmologists. Independent test data were derived from the population-based CHES, a community-based clinic in Singapore, and a hospital-based clinic at the University of Southern California (USC). Classifier performance was evaluated with receiver operating characteristic curve and area under the receiver operating characteristic curve (AUC) metrics. Interexaminer agreement between the classifier and two human examiners at USC was calculated using Cohen's kappa coefficients.

resultsThe classifier was tested using 640 images (311 open and 329 closed) from 127 Chinese Americans, 10 165 images (9595 open and 570 closed) from 1318 predominantly Chinese Singaporeans and 300 images (234 open and 66 closed) from 40 multiethnic USC patients. The classifier achieved similar performance in the CHES (AUC=0.917), Singapore (AUC=0.894) and USC (AUC=0.922) cohorts. Standardising the distribution of gonioscopy grades across cohorts produced similar AUC metrics (range 0.890-0.932). The agreement between the CNN classifier and two human examiners (Ҡ=0.700 and 0.704) approximated interexaminer agreement (Ҡ=0.693) in the USC cohort.

conclusionAn OCT-based deep learning classifier demonstrated consistent performance detecting gonioscopic angle closure across three independent patient populations. This automated method could aid ophthalmologists in the assessment of angle status in diverse patient populations.

Indexed as

Deep LearningGlaucoma, Angle-ClosureAnterior Eye SegmentGonioscopyHospitalsHumansIntraocular PressureTaurineTomography, Optical Coherence2-(N-cyclohexylamino)ethanesulfonic acidTaurineanterior chamberdiagnostic tests/investigationglaucomaimaging

Identifiers

PMID34670749
PMCPMC9018872
OpenAlexW3206644351

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.