Evidence map›Paper›PMID 34670592›Full record

ArticleJournal of orthopaedic surgery and research2021

Polymethyl methacrylate cure time in simulated in vivo total knee arthroplasty versus in vitro conditions.

Daniel A Funk, Quang-Viet Nguyen, Michael Swank

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Modalities of failure of cement-augmented pedicle screws.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Daniel A Funkc/o Cincinnati Ortho Research Institute, 500 E Business Way, Sharonville, OH, 45241, USA. Dfunk.cinci@gmail.com.ORCID http://orcid.org/0000-0001-5315-2647
Quang-Viet NguyenRFA Systems, LLC, 24790 Gypsum Way, Aldie, VA, 20105, USA.
Michael Swankc/o Cincinnati Ortho Research Institute, 500 E Business Way, Sharonville, OH, 45241, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present means of confirming the cure of intra-operative polymethyl methacrylate (PMMA) cement are to wait for the remainder cement to harden. To our knowledge, there is no available technique to determine the precise moment of cure for in-vivo cement beneath the tibial tray. This study uses a novel means to determine cement curing time in two environments. One environment represents the operating theater, and the other environment attempts to model cement conditions under the tibial tray during surgery. MATERIALS AND

methodsWe determined the temperature-versus-time plot of cement curing using the following two temperature sensors: one in a simulated implanted tibial tray and another in the remainder cement. We performed 55 tests using dental methyl methacrylate cement mixed in the same ratio as the orthopedic cement. To simulate in vivo conditions, a simulated stainless-steel tibial tray was implanted on a cancellous bone substitute (Sawbones, Vashon Island, WA, USA) using standard cement technique and subsequently placed in a 90°F (32.2 °C) circulating water bath. We positioned a temperature sensor in the cement mantel and positioned a second sensor in a portion of the remaining cement. The temperature from both sensors was measured simultaneously, beginning at 5 min after mixing and continuing for 20 min. The first derivative of the temperature provided the precise curing time for each condition. We analyzed the results of 55 repeated experiments with an independent samples t-test.

resultsWith the described technique, we were able to accurately determine the moment of cure of the cement beneath the simulated tray. There was a mean difference between cure time of 5 min and 26 s (p value < 0.001) between the two conditions.

conclusionsWe validated that our technique was successful in determining the precise time to cure in two different environments. LEVEL OF EVIDENCE: This was not a clinical trial and did not involve patients as such the level of evidence was Grade A: Consistent 1 and 2.

Indexed as

Arthroplasty, Replacement, KneeBone CementsHumansPolymethyl MethacrylateTemperatureTibiaBone CementsPolymethyl MethacrylateCement cure timeCementing total knee arthroplastyCement temperatureCement temperature sensorTotal knee arthroplasty cement cure

Identifiers

PMID34670592
PMCPMC8527682

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.