ArticleJournal of clinical and translational research2021
Can leaded glasses protect the eye lens in patients undergoing neck computed tomography?
Article in Journal of clinical and translational research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND AND
aimsComputed tomography (CT) is one of the main sources using ionizing radiation. Considering the toxicity from this radiation, any technique that could reduce the radiosensitive organs' doses without affecting the image diagnostic quality must be considered in routine practice. In this study, the amount of eye lens dose reduction in the presence of radioprotective glasses was evaluated in neck CT examinations.
methodsThirty adult patients (15 men and 15 women) with a mean age of 44.6 years undergoing neck CT examination participated in this study. For each patient, six thermoluminescent dosimeters (TLDs-100) were attached above the eye lens glasses surface, and another six under the glasses to assess the radioprotective effect of the glasses. The TLDs were readout and converted to Hp (3) as an indicator of eye lens dose. The obtained results from the TLD readouts as eye lens dose were compared using a paired t-test.
resultsThe TLD measurements showed the mean±standard deviation values of 2.97±0.61 mGy and 1.04±0.16 mGy for TLDs above and under the radioprotective glasses, respectively. The radioprotective glasses significantly decreased the eye lens dose by about 64.9% (
conclusionsDue to the results, wearing radioprotective glasses for patients during neck CT scans could significantly reduce the eye lens doses. RELEVANCE FOR PATIENTS: The outcome of this research shows that leaded glasses can decrease the received dose significantly in patient during neck CT scans.
Indexed as
Identifiers
34667888PMC8520700W3205700853What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.