Evidence map›Paper›PMID 34661856›Full record

ArticleMedical & biological engineering & computing2021

Enhancement and denoising method for low-quality MRI, CT images via the sequence decomposition Retinex model, and haze removal algorithm.

Lei Chen, Chen Tang, Min Xu, Zhenkun Lei

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. A customized acutance metric for quality control applications in MRI.Medical & biological engineering & computing · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Lei ChenSchool of Electrical and Information Engineering, Tianjin University, Tianjin, 300072, People's Republic of China.
Chen TangSchool of Electrical and Information Engineering, Tianjin University, Tianjin, 300072, People's Republic of China. tangchen@tju.edu.cn.
Min XuSchool of Electrical and Information Engineering, Tianjin University, Tianjin, 300072, People's Republic of China.
Zhenkun LeiState Key Laboratory of Structural Analysis for Industrial Equipment, Dalian University of Technology, Dalian, 116024, People's Republic of China.

Funding

National Natural Science Foundation of China 11772081National Natural Science Foundation of China 11972106
6 · The paper itself

Abstract

The visibility and analyzability of MRI and CT images have a great impact on the diagnosis of medical diseases. Therefore, for low-quality MRI and CT images, it is necessary to effectively improve the contrast while suppressing the noise. In this paper, we propose an enhancement and denoising strategy for low-quality medical images based on the sequence decomposition Retinex model and the inverse haze removal approach. To be specific, we first estimate the smoothed illumination and de-noised reflectance in a successive sequence. Then, we apply a color inversion from 0-255 to the estimated illumination, and introduce a haze removal approach based on the dark channel prior to adjust the inverted illumination. Finally, the enhanced image is generated by combining the adjusted illumination and the de-noised reflectance. As a result, improved visibility is obtained from the processed images and inefficient or excessive enhancement is avoided. To verify the reliability of the proposed method, we perform qualitative and quantitative evaluation on five MRI datasets and one CT dataset. Experimental results demonstrate that the proposed method strikes a splendid balance between enhancement and denoising, providing performance superior to that of several state-of-the-art methods.

Indexed as

AlgorithmsMagnetic Resonance ImagingReproducibility of ResultsTomography, X-Ray ComputedHaze removalImage processingLow-quality imageRetinex

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked