ArticleFrontiers in oncology2021
First-In-Human Study in Cancer Patients Establishing the Feasibility of Oxygen Measurements in Tumors Using Electron Paramagnetic Resonance With the OxyChip.
Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 26 citations in OpenAlex.
- First Clinical-Scale Use of a Percutaneous EPR Oxygen Probe (OxyTrack) for Deep-Tissue pOMagnetic resonance in medicine · 2026Article
- Real-Time Monitoring of Tissue Oxygenation During Hyperbaric Oxygen Exposure Using In Vivo EPR Oximetry.Magnetic resonance in medicine · 2026Article
- Continuous-Wave Electron Paramagnetic Resonance Spectroscopy in Pharmaceutical Research: Current Applications and Emerging Opportunities.Pharmaceuticals (Basel, Switzerland) · 2026Review
- Combining Oxygen-Enhanced MRI and Electron Paramagnetic Resonance Oximetry for Quantitative OE-MRI (qOE-MRI) as a Method for Mapping Absolute Oxygen Levels (pOMagnetic resonance in medicine · 2026Article
- Quantitative longitudinal photoacoustic imaging of vascular oxygenation for therapy response monitoring in Non-Hodgkin lymphoma.Photoacoustics · 2026Article
- Electron paramagnetic resonance (EPR) meets drug delivery and biomaterials: a magnetic love story.Drug delivery and translational research · 2026Review
- OxyTrack: A Novel Needle Sensor for In Situ Oximetry.Magnetic resonance in medicine · 2026Article
- 3D Printing of Oxygen-Sensing ECM-Based Skin Graft for Personalized Treatment of Chronic Wounds-A Technological Proof of Concept.Journal of functional biomaterials · 2026Article
- Reconfigurable animal bed-EPR resonator assembly for multimodal co-registration.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026Article
- Computationally efficient 4D spectral-spatial EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025Article
- Composite spin probes with adjustable oxygen sensitivity for pulse electron paramagnetic resonance imaging.Magnetic resonance in medicine · 2025Article
- Evaluation of Mesoporous Silica Nanoparticles as Carriers of Triarylmethyl Radical Spin Probes for EPR Oximetry.The journal of physical chemistry. B · 2025Article
- Hand-held electron spin resonance scanner for subcutaneous oximetry using OxyChip.Magnetic resonance in medicine · 2024Article
- SOX71, A Biocompatible Succinyl Derivative of the Triarylmethyl Radical OX071 for In Vivo Quantitative Oxygen Mapping Using Electron Paramagnetic Resonance.Molecular imaging and biology · 2024Article
- Highly Sensitive Detection of Melanin in Melanomas Using Multi-harmonic Low Frequency EPR.Molecular imaging and biology · 2024Article
- Oxygen Imaging of a Rabbit Tumor Using a Human-Sized Pulse Electron Paramagnetic Resonance Imager.Molecular imaging and biology · 2024Article
- Towards Characterization of Skin Melanoma in the Clinic by Electron Paramagnetic Resonance (EPR) Spectroscopy and Imaging of Melanin.Molecular imaging and biology · 2024Review
- Surface dielectric resonator for in vivo EPR measurements.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024Article
- Sensitive simultaneous measurements of oxygenation and extracellular pH by EPR using a stable monophosphonated trityl radical and lithium phthalocyanine.Free radical biology & medicine · 2024Article
- Biocompatible Monophosphonated Trityl Spin Probe, HOPE71, for In Vivo Measurement of pOAnalytical chemistry · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
25 authors at 2 institutions in 1 country.
Funding
Abstract
objectiveThe overall objective of this clinical study was to validate an implantable oxygen sensor, called the 'OxyChip', as a clinically feasible technology that would allow individualized tumor-oxygen assessments in cancer patients prior to and during hypoxia-modification interventions such as hyperoxygen breathing.
methodsPatients with any solid tumor at ≤3-cm depth from the skin-surface scheduled to undergo surgical resection (with or without neoadjuvant therapy) were considered eligible for the study. The OxyChip was implanted in the tumor and subsequently removed during standard-of-care surgery. Partial pressure of oxygen (pO
resultsTwenty-three cancer patients underwent OxyChip implantation in their tumors. Six patients received neoadjuvant therapy while the OxyChip was implanted. Median implant duration was 30 days (range 4-128 days). Forty-five successful oxygen measurements were made in 15 patients. Baseline pO
conclusionsMeasurement of baseline pO
Indexed as
Identifiers
What OpenQuestion holds