Evidence map›Paper›PMID 34660085›Full record

ArticleCureus2021

Real-World Clinical Outcomes of Indigenous Biodegradable Polymer Drug-Eluting Stents.

Basant Kumar, Raikot Rakesh Ram, Neelam Dahiya, Atit A Gawalkar

Abstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Basant KumarCardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, IND.
Raikot Rakesh RamInternal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, IND.
Neelam DahiyaCardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, IND.
Atit A GawalkarCardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction The durable polymer has been shown to cause neoatherosclerosis, and chronic local inflammation, predisposing individuals to in-stent restenosis and stent thrombosis (ST). The biodegradable polymer stents, which degrade after the desired function of drug release is achieved, allow for endothelial healing. Indigenous coronary stent manufacturing and its use are on the rise nowadays, and their safety and efficacy have been studied in well-structured clinical trials. However, data are scarce on their safety and efficacy in the real-world clinical setting. In this study, we examine the real-world one-year performance of bioresorbable or polymer-free stents manufactured in India. Materials and methods This was a single-center, single-arm prospective observational study involving 210 patients undergoing intracoronary stenting using bioabsorbable or polymer-free drug-eluting stents (DES) from Indian manufacturers. All patients were followed up for 12 months prospectively for any major clinical events. Results The mean age of the enrolled patients was 57.04 years (IQR: 34-84 years), among which 159 (75.7%) were male; 99 (43.8%) patients had presented with acute myocardial infarction (MI). A total of 294 stents were deployed with a mean diameter of 3.1 ±0.4 mm, and a mean length of 29.4 ±9.1 mm. Two patients had experienced major adverse cardiovascular events (MACE). After three months of follow-up, one patient developed ST, and the same patient developed a cerebrovascular accident (CVA) after six months. After one year of follow-up, one patient died of cardiac causes. Conclusion Based on our findings, in the real-world clinical setting, the indigenously made biodegradable polymer DES are both safe and effective.

Indexed as

bioabsorbable coronary stentsbiodegradable coronary stentscoronary interventionindigenous stentsnewer generation stents

Identifiers

PMID34660085
PMCPMC8503863

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.