ArticleCureus2021
Real-World Clinical Outcomes of Indigenous Biodegradable Polymer Drug-Eluting Stents.
Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction The durable polymer has been shown to cause neoatherosclerosis, and chronic local inflammation, predisposing individuals to in-stent restenosis and stent thrombosis (ST). The biodegradable polymer stents, which degrade after the desired function of drug release is achieved, allow for endothelial healing. Indigenous coronary stent manufacturing and its use are on the rise nowadays, and their safety and efficacy have been studied in well-structured clinical trials. However, data are scarce on their safety and efficacy in the real-world clinical setting. In this study, we examine the real-world one-year performance of bioresorbable or polymer-free stents manufactured in India. Materials and methods This was a single-center, single-arm prospective observational study involving 210 patients undergoing intracoronary stenting using bioabsorbable or polymer-free drug-eluting stents (DES) from Indian manufacturers. All patients were followed up for 12 months prospectively for any major clinical events. Results The mean age of the enrolled patients was 57.04 years (IQR: 34-84 years), among which 159 (75.7%) were male; 99 (43.8%) patients had presented with acute myocardial infarction (MI). A total of 294 stents were deployed with a mean diameter of 3.1 ±0.4 mm, and a mean length of 29.4 ±9.1 mm. Two patients had experienced major adverse cardiovascular events (MACE). After three months of follow-up, one patient developed ST, and the same patient developed a cerebrovascular accident (CVA) after six months. After one year of follow-up, one patient died of cardiac causes. Conclusion Based on our findings, in the real-world clinical setting, the indigenously made biodegradable polymer DES are both safe and effective.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.