Evidence map›Paper›PMID 34660009›Full record

ArticleCureus2021

Dosimetry Comparison of Palliative Radiation Plans Generated From Available Diagnostic CT Images Versus Dedicated CT Simulation for Inpatients.

Quoc-Anh Ho, Lexie Smith-Raymond, Angela Locke, Jared R Robbins

Abstract read
In one paragraph

Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Quoc-Anh HoRadiation Oncology, The University of Arizona College of Medicine - Tucson, Tucson, USA.
Lexie Smith-RaymondRadiation Oncology, Banner - University Medical Center Tucson, Tucson, USA.
Angela LockeRadiation Oncology, Banner - University Medical Center Tucson, Tucson, USA.
Jared R RobbinsRadiation Oncology, The University of Arizona College of Medicine - Tucson, Tucson, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction The morbidity sequelae of advanced cancer are often irreversible. Early palliative radiation can prevent, delay, and even improve these consequences. Treatment may be delayed due to a packed computed tomography (CT) simulation schedule or other logistics, including the cost and burden of arranging ambulance transportation when radiation centers are off-site. Objectives The primary objective was to determine the feasibility of using a recent diagnostic CT scan in lieu of a dedicated simulation CT to generate an adequate plan without sacrificing dosimetric goals and subsequent efficacy or tolerability. Secondary objectives included how much the lesion has grown, and how much earlier treatment could start if planned on a diagnostic CT scan. Materials/Methods For each inpatient treated with palliative radiation, a prior recent diagnostic CT scan was imported into the RayStation (RaySearch Laboratories, Stockholm, Sweden) planning system. From these diagnostic scans, planning treatment volumes (PTV) and organs at risk (OAR) were contoured using the same technique as the patient's actual treatment. The primary outcome was to compare both the PTV coverage and OAR dose between the plan generated from the diagnostic CT compared to that from the simulation CT. Our secondary outcomes include the mean time between CT simulation and first treatment, change in tumor volume between diagnostic scan and CT simulation, and the hottest 1% of each plan (D1). Results Between May and August 2019, a total of 22 inpatients were treated palliatively. Of those 22 patients, 10 patients (ages 32-92 years, median 64.5 years, 50% spine) met study criteria and had a diagnostic CT scan that was obtained within 14 days of simulation CT that was also compatible with our planning software. In the plans that were delivered, a mean of 98.8% (range 94.4-100%) of PTV was covered by at least 95% prescription dose. In the diagnostic CT plans, a mean of 95.4% (range 84.5-100%) of PTV was covered by at least 95% prescription dose. The difference between plans trended towards significance (p=0.061). When looking at patients receiving treatment to the spine or having a diagnostic CT within four days of the simulation CT, there was no statistically significant difference between the two plans (p=0.032 and 0.030, respectively). The OARs received, on average, 1.4% less mean radiation dose in the hypothetical plans (p=0.911). All OAR constraints were met in both groups. The mean time between diagnostic CT and CT simulation was 5.9 days and between CT simulation and first treatment was 1.9 days (range 0-5 days). The mean change in tumor volume was 22.64% smaller in the diagnostic CT scan plan. The D1 was an average 1% hotter in the hypothetical plans (p=0.16). Conclusion In hospitalized patients with an indication for palliative radiation, treatment planning on a pre-existing recent diagnostic CT scan produces comparable dose distributions without increases in dose to OARs when compared to the use of CT simulation scans, particularly for the treatment of the spine or when a very recent diagnostic CT is available. Bypassing CT simulation in select cases allows for earlier delivery of radiation with less patient and logistical burden. In combination with daily image guidance, this may translate to more timely delivery of radiation, less cost and burden to critically ill patients, and improved palliative benefit.

Indexed as

dosimetrymedical physicspalliativeradiationradiation oncologyspinal cord compression

Identifiers

PMID34660009
PMCPMC8496742

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.