Evidence map›Paper›PMID 34655182›Full record

ArticleJournal of biomedical optics2021

Accurate and stable two-step LED position calibration method for Fourier ptychographic microscopy.

Haojie Wei, Jing Du, Lei Liu, Yu He, Yong Yang, Song Hu, Yan Tang

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Haojie WeiInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Jing DuInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Lei LiuInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Yu HeInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Yong YangInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Song HuInstitute of Optics and Electronics, Chinese Academy of Sciences, China.
Yan TangInstitute of Optics and Electronics Chinese Academy of Sciences, State Key Laboratory of Optical Tec, China.
Institute of Optics and Electronics, Chinese Academy of Sciences · CNChinese Academy of Sciences · CNUniversity of Chinese Academy of Sciences · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceFourier ptychography microscopy (FPM) is a computational optical imaging technology that employs angularly varying illuminations and a phase retrieval algorithm to achieve a wide field of view and high-resolution imaging simultaneously. In the FPM, LED position error will reduce the quality of the reconstructed high-resolution image. To correct the LED positions, current methods consider each of the LED positions as independent and use an optimization algorithm to get each of the positions. When the positional misalignment is large or the search position falls into a local optimal value, the current methods may lack stability and accuracy.

aimWe improve the model of the LED position and propose an accurate and stable two-step correction scheme (tcFPM) to calibrate the LED position error. APPROACH: The improved LED positions model combines the overall offset, which represents the relative deviation of the LED array and the optical axis, with the slight deviation of each LED's independent position. In the tcFPM, the overall offset of the LED array is corrected at first, which obtains an approximate value of the overall offset of the LED array. Then the position of each LED is precisely adjusted, which obtains the slight offset of each LED.

resultsThis LED position error model is more in line with the actual situation. The simulation and experimental results show that the method has high accuracy in correcting the LED position. Furthermore, the reconstruction process of tcFPM is more stable and significantly improves the quality of the reconstruction results, which is compared with some LED position error correction methods.

conclusionsAn LED position error correction technology is proposed, which has a stable iterative process and improves the reconstruction accuracy of complex amplitude.

Indexed as

AlgorithmsMicroscopyCalibrationFourier AnalysisLightingcomputational imagingFourier ptychographic microscopypositional misalignment correction

Identifiers

PMID34655182
PMCPMC8517127
OpenAlexW3206526006

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.