Evidence map›Paper›PMID 34654877›Full record

ArticleScientific reports2021

Resolution-enhanced OCT and expanded framework of information capacity and resolution in coherent imaging.

Nichaluk Leartprapun, Steven G Adie

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Nichaluk LeartprapunNancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA.
Steven G AdieNancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA. sga42@cornell.edu.
Cornell University · US

Funding

Real-time Aberration Sensor for Large-Scale Microscopy Deep in the Mouse and Adult Zebrafish BrainR01NS120819 · NINDS · CORNELL UNIVERSITY · PI ADIE, STEVEN GRAHAM · 2021 to 2021
$2.0M
Volumetric time-lapse imaging of biophysical cell-extracellular matrix interactions for systems mechanobiology researchR01GM132823 · NIGMS · CORNELL UNIVERSITY · PI ADIE, STEVEN GRAHAM · 2019 to 2022
$1.7M
NIGMS NIH HHS R01 GM132823NIH HHS NIBIB-R01GM132823NINDS NIH HHS R01 NS120819
6 · The paper itself

Abstract

Spatial resolution in conventional optical microscopy has traditionally been treated as a fixed parameter of the optical system. Here, we present an approach to enhance transverse resolution in beam-scanned optical coherence tomography (OCT) beyond its aberration-free resolution limit, without any modification to the optical system. Based on the theorem of invariance of information capacity, resolution-enhanced (RE)-OCT navigates the exchange of information between resolution and signal-to-noise ratio (SNR) by exploiting efficient noise suppression via coherent averaging and a simple computational bandwidth expansion procedure. We demonstrate a resolution enhancement of 1.5 × relative to the aberration-free limit while maintaining comparable SNR in silicone phantom. We show that RE-OCT can significantly enhance the visualization of fine microstructural features in collagen gel and ex vivo mouse brain. Beyond RE-OCT, our analysis in the spatial-frequency domain leads to an expanded framework of information capacity and resolution in coherent imaging that contributes new implications to the theory of coherent imaging. RE-OCT can be readily implemented on most OCT systems worldwide, immediately unlocking information that is beyond their current imaging capabilities, and so has the potential for widespread impact in the numerous areas in which OCT is utilized, including the basic sciences and translational medicine.

Indexed as

Image Interpretation, Computer-AssistedSignal-To-Noise RatioTomography, Optical CoherenceAnimalsBrainMiceMice, Inbred C57BLPhantoms, Imaging

Identifiers

PMID34654877
PMCPMC8521598
OpenAlexW3205295130

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.