ArticleBiosensors & bioelectronics2022
A fiber optic photoacoustic sensor for real-time heparin monitoring.
Article in Biosensors & bioelectronics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Polyphenol-stabilized coacervates for enzyme-triggered drug delivery.Nature communications · 2024Article
- Colorimetric sensing for translational applications: from colorants to mechanisms.Chemical Society reviews · 2024Review
- Unpacking the packaged optical fiber bio-sensors: understanding the obstacle for biomedical application.Frontiers in bioengineering and biotechnology · 2024Review
- Article
- The sound of blood: photoacoustic imaging in blood analysis.Medicine in novel technology and devices · 2023Article
- Exploiting Plasmonic Phenomena in Polymer Optical Fibers to Realize a Force Sensor.Sensors (Basel, Switzerland) · 2022Article
- Peptidic Sulfhydryl for Interfacing Nanocrystals and Subsequent Sensing of SARS-CoV-2 Protease.Chemistry of materials : a publication of the American Chemical Society · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
Heparin is a common anticoagulant, but heparin overdose is a common intensive care unit (ICU) medication error due to the narrow therapeutic window of heparin. Conventional methods to monitoring heparin suffer from long turnaround time, the need for skilled personnel, and low frequency of sampling. To overcome these issues, we describe here a fiber optic photoacoustic (PA) sensor for real-time heparin monitoring. The proposed sensor was validated with in vitro testing and in a simulated in vivo model using the following samples: (1) phosphate-buffered saline (PBS), (2) spiked human plasma, (3) spiked whole human blood, and (4) clinical samples from patients treated with heparin. Samples were validated by comparing the PA signal to the activated partial thromboplastin time (aPTT) as well as the activated clotting time (ACT). Importantly, the proposed sensor has a short turnaround time (3 min) and a limit of detection of 0.18 U/ml in whole human blood. The PA signal is linear with heparin dose and correlates with the aPTT value (Pearson's r = 0.99). The PA signal from 32 clinical samples collected from eight patients linearly correlated with ACT values (Pearson's r = 0.89, in vitro; Pearson's r = 0.93, simulated in vivo). The PA signal was also validated against the cumulative heparin dose (Pearson's r = 0.94, in vitro; Pearson's r = 0.96, simulated in vivo). This approach could have applications in both in vitro and real-time in vivo heparin monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials