Trial reportArchives of orthopaedic and trauma surgery2021
Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study.
Trial report in Archives of orthopaedic and trauma surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Sensor-guided gap balance versus manual gap balance in primary total knee arthroplasty: a meta-analysis.Journal of orthopaedic surgery and research · 2022Pooled it
- Article
- Accuracy and clinical outcomes in total knee arthroplasty using an image-free navigation system.Archives of orthopaedic and trauma surgery · 2025Article
- Is bone remodelling around fully hydroxyapatite-coated and tapered-wedge stems related to the stem fixation pattern?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- Effect of implant composition on periprosthetic bone mineral density after total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2023Article
- The learning curve associated with imageless navigation in total knee arthroplasty.Archives of orthopaedic and trauma surgery · 2023Article
- Fully hydroxyapatite-coated compaction broached and triple-tapered stem may reduce the risk of stress shielding after primary total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2022Article
- Machine Learning Algorithm to Predict Worsening of Flexion Range of Motion After Total Knee Arthroplasty.Arthroplasty today · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIt remains to be established whether optical computed tomography (CT)-free and acceleration-based navigation systems differ in terms of implantation accuracy and clinical outcomes for total knee arthroplasty. This randomised prospective study compared the implantation accuracy of these two navigation systems in total knee arthroplasty.
methodsOptical CT-free navigation (ExactechGPS) or acceleration-based navigation (KneeAlign2) was randomly assigned to the left or right knee of 45 patients who underwent a single-stage bilateral total knee arthroplasty: the ExactechGPS (n = 45) and KneeAlign2 groups (n = 45) were compared. Component alignments were evaluated using three-dimensional computed tomography and radiography at pre- and post-surgery. Implantation accuracy of the component alignment, proportion of outliers, postoperative range of motion, and Japanese Orthopaedic Association (JOA) score were compared between the systems.
resultsThe implantation accuracies of the lower-extremity mechanical alignment, coronal femoral component angle, coronal tibial component angle, sagittal femoral component, axial femoral angle, and axial tibial angle had no significant difference between the groups. The implantation accuracy of the sagittal tibial component angle was superior in the ExactechGPS than the KneeAlign2 group (1.3° vs. 1.8°, P = 0.034). The proportions of outliers, range of motion, and JOA score had no significant difference between the groups.
conclusionIn the tibial sagittal plane, there was a significant difference in the implantation accuracy, but its difference did not affect the clinical outcomes. Both navigation systems have clinically acceptable implantation accuracy.
Indexed as
Identifiers
34652514What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.