Evidence map›Paper›PMID 34650174›Full record

ArticleScientific reports2021

Comparative analysis of high-speed videolaryngoscopy images and sound data simultaneously acquired from rigid and flexible laryngoscope: a pilot study.

Wioletta Pietruszewska, Marcin Just, Joanna Morawska, Jakub Malinowski, Joanna Hoffman, Anna Racino, Magda Barańska, Magdalena Kowalczyk, Ewa Niebudek-Bogusz

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Supraglottic Laryngeal Maneuvers in Adductor Laryngeal Dystonia During Connected Speech.Journal of voice : official journal of the Voice Foundation · 2024
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Wioletta PietruszewskaDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland. wioletta.pietruszewska@umed.lodz.pl.
Marcin JustDiagnova Technologies, Wroclaw Technology Park, Wroclaw, Poland.
Joanna MorawskaDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.
Jakub MalinowskiDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.
Joanna HoffmanDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.
Anna RacinoDiagnova Technologies, Wroclaw Technology Park, Wroclaw, Poland.
Magda BarańskaDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.
Magdalena KowalczykDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.
Ewa Niebudek-BoguszDepartment of Otolaryngology, Head and Neck Oncology, Medical University of Lodz, Lodz, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-Speed Videoendoscopy (HSV) is becoming a robust tool for the assessment of vocal fold vibration in laboratory investigation and clinical practice. We describe the first successful application of flexible High Speed Videoendoscopy with innovative laser light source conducted in clinical settings. The acquired image and simultaneously recorded audio data are compared to the results obtained by means of a rigid endoscope. We demonstrated that the HSV recordings with fiber-optic laryngoscope have enabled obtaining consistently bright, color images suitable for parametrization of vocal fold oscillation similarly as in the case of the HSV data obtained from a rigid laryngoscope. The comparison of period and amplitude perturbation parameters calculated on the basis of image and audio data acquired from flexible and rigid HSV recording objectively confirm that flexible High-Speed Videoendoscopy is a more suitable method for examination of natural phonation. The HSV-based measures generated from this kymographic analysis are arguably a superior representation of the vocal fold vibrations than the acoustic analysis because their quantification is independent of the vocal tract influences. This experimental study has several implications for further research in the field of HSV application in clinical assessment of glottal pathologies nature and its effect on vocal folds vibrations.

Indexed as

PhonationAcousticsAdultFemaleGlottisHumansKymographyLaryngoscopesLaryngoscopyMiddle AgedPilot ProjectsVibrationVideo RecordingVocal Cords

Identifiers

PMID34650174
PMCPMC8516923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.